Eaton 9PX11KIRTG2 uninterruptible power supply (UPS) Double-conversion (Online) 11 kVA 11000 W 12 AC outlet(s)
- Form factor: Rackmount/Tower
- Product colour: Black, Silver
- UPS topology: Double-conversion (Online)
- Output power capacity: 11 kVA
- Output power: 11000 W
- Overload protection
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Eaton’s 9PX Gen2 5-11kW UPS further strengthens our proven 9PX power protection solution through advanced technology upgrades and customer-centric enhancements.
Efficiency of up to 97.2% in the 11kW 4U, 9PX Gen2 is the compact UPS that also leads the way.
9PX Gen 2 along with cybersecure Gigabit Network Card can leverage predictive machine learning to identify battery replacements minimising downtime and maximising uptime.
9PX Gen2 delivers best-in-class power management and battery backup for critical equipment in data centres, distributed IT, edge networks, network closets and server rooms.
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 11 kVA
- Output powerThe power that the device can produce.
- 11000 W
- Overload protectionIndicates whether the device includes a safety mechanism to prevent damage caused by electrical or mechanical overstress.
- Yes
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
- Sustainability certificatesThe environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).
- ENERGY STAR
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Show all 48 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
- Control typeThe way in which the device is controlled.
- Buttons
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 11 kVA
- Output powerThe power that the device can produce.
- 11000 W
- Rack capacityThe spase that device fill in rack.
- 4U
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 176 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 276 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 200 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Efficiency (On-line mode)The ratio of output power to input power when the device is operating in on-line mode, measured in %.
- 96.7%
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Overload capacity (10 minutes)The maximum percentage of the rated load that the unit can sustain for a duration of 10 minutes without failure, measured in %.
- 125%
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 1%
Other features
- Overload protectionIndicates whether the device includes a safety mechanism to prevent damage caused by electrical or mechanical overstress.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 440 mm
- DepthThe distance from the front to the back of something.
- 725 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 174 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 78.8 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, Federal Communications Commission (FCC), CB, TÜV mark, UL
Packaging content
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
Sustainability
- Sustainability certificatesThe environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).
- ENERGY STAR
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Automatic battery testIndicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, Terminal, C19 coupler
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- Terminal
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 12 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type-B
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
- Remote Power Off (RPO)/Remote On-Off (ROO) connectorIndicates whether the device features a dedicated connector for remote power off (RPO) or remote on-off (ROO) functionality.
- Yes
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 38 dB
Power
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overdischarge, Short circuit
Packaging data
- Package typeThe type of product package e.g. box.
- Box
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 9E6KIR uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
5400 W 1 AC outlet(s)

Eaton BC1500RT1ULNC uninterruptible power supply (UPS) Standby (Offline) 1.44 kVA
1050 W 6 AC outlet(s)

Eaton 9E11KIR uninterruptible power supply (UPS) Double-conversion (Online) 11 kVA
10000 W

Eaton 93PX15KHW uninterruptible power supply (UPS) Double-conversion (Online) 15 kVA

Eaton 9E11KIPMR uninterruptible power supply (UPS) Double-conversion (Online) 11 kVA
10000 W