Eaton 93PS uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA 10000 W
- Form factor: Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 10 kVA
- Output power: 10000 W
- Nominal output voltage: 400 V
All 43 specificationsProduct page at powerquality.eaton.com ↗
Versions
IEC 62040-1, IEC 62040-2, IEC 62040-3 · 64 · 335 mm
IEC 62040-1, IEC 62040-2, IEC 62040-3 · 128 · 480 mm
IEC 62040-2, IEC 62040-3 · 64 · 335 mm
IEC 62040-2, IEC 62040-3 · 64 · 480 mm
6 model numbers for IEC 62040-1, IEC 62040-2, IEC 62040-3 · 64 · 335 mm
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Efficiency
- Above 96% efficiency in double conversion mode
- Up to 99% efficiency with Energy Saver System
Scalability
- Scalable architecture and ‘Pay as you grow’ capability to minimise Capital Expenditure
- Paralleling of up to 4 units
Inherent redundancy
- Modular design allows internal redundancy (separate battery configuration also available)
Smallest footprint in the market
The 93PS provides significantly more in a smaller package, with a footprint of only 0.25 m² for the smaller frame (8-20 kW) and 0.36 m² for the large frame (8-40 kW)
Unity power factor (1.0)
Hot Swap and Hot Scalable
- A module can be replaced while the other continues protecting the load (concurrent maintenance)
- A module can be added while the other continues protecting the load (hot scalable)
- Individual battery strings can be serviced while other strings are supporting the load
Super-sized static switch
Optional super-sized Static Switch to enhance the selectivity of the overall electrical installation
Safety
- Equipped with an ultra-rapid fuse in the Static Switch – ensuring safety in all scenarios
- Equipped with a backfeed contactor – no need for additional installments
Cloud & Virtualisation ready
- The 93PS and Eaton’s Intelligent Power Manager software suite takes the resiliency of the system to the next level by bridging the electrical and IT infrastructure
- IT and electrical infrastructure management from a “Single pane of glass”
- Load shedding – 50% drop in load equates to 250% more runtime!
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 10000 W
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 400 V
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 400 V
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- Intelligent Power Software suite
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC 62040-1, IEC 62040-2, IEC 62040-3
- Management card includedIndicates whether a dedicated network management card for remote monitoring and control is included with the unit.
- Yes
Show all 43 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 10000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 380 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 415 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 380 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 96%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 1
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 4%
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 400 V
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 400 V
- Number of batteries supportedThe number of batteries that can be used with the product.
- 64
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Software
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- Intelligent Power Software suite
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 335 mm
- DepthThe distance from the front to the back of something.
- 750 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1300 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 252 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC 62040-1, IEC 62040-2, IEC 62040-3
Packaging content
- Management card includedIndicates whether a dedicated network management card for remote monitoring and control is included with the unit.
- Yes
Safety regulation & standards
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- IEC 62040-1
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 5 - 45 °C
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Automatic battery testIndicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.
- Yes
Ports & interfaces
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 1
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 60 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 93PS uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA
8000 W

Eaton 93PM uninterruptible power supply (UPS) Double-conversion (Online)
50000 W

Eaton 93PS uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA
40000 W

Eaton 93PM uninterruptible power supply (UPS) Double-conversion (Online)
50000 W

Eaton 93PS uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA
30000 W

Eaton 93PM uninterruptible power supply (UPS) Double-conversion (Online)
40000 W