Eaton 93PM G2 UPS uninterruptible power supply (UPS) Double-conversion (Online) 240 kVA 216000 W
- Form factor: Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 240 kVA
- Output power: 216000 W
- Input connection type: Fixed
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Highest availability, at the lowest total cost of ownership
Lowest Total Cost of Ownership (TCO)
- Highest efficiency in its power range with up to 97% efficiency in double conversion mode and >99 % efficiency in Energy Saver System mode
- High efficiency even when UPS load levels are low, optimized by Variable Module Management System (VMMS)
- Maximal power and energy density ensures a compact footprint
- EnergyAware ready – Revenue from a necessary investment
Ultimate resiliency
- HotSync patented load-sharing technology eliminates risk of single point of failure
- Equipped with ultra-rapid fuses in the Static Switch – ensuring safety in all scenarios
- Equipped with a backfeed contactor – no need for additional installments
Higly scalable and easy deployment
- Modularity - Hot swappable power modules can be replaced or added while other modules continue protecting the load
- Thermal management allows for flexible installation against the wall, in rows and in hot/cold aisle configurations
Easy management
- Wide range of connectivity options (Web/SNMP, Modbus/Jbus, relay contacts)
- Intelligent Power software integrates with leading virtualization management systems for monitoring and managing
- The intuitive touchscreen LCD user interface and visual data logging provides clear information on the UPS status
- Cyber-secure (third party certified) connectivity
Documents
- ManualUser manual ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 240 kVA
- Output powerThe power that the device can produce.
- 216000 W
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- Fixed
- Output connection typeThe type of connection used for outputs from this device e.g. USB.
- Fixed
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC/EN 62040-2 IEC/EN 62040-1 EN 62040-3
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Show all 41 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- ModularIndicates whether the unit features a modular design that allows for the expansion or replacement of individual components.
- Yes
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 240 kVA
- Output powerThe power that the device can produce.
- 216000 W
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 380 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 415 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 380 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 97%
- Efficiency (On-line mode)The ratio of output power to input power when the device is operating in on-line mode, measured in %.
- 99%
- Efficiency (ECO mode)The energy efficiency of the device when operating in its power-saving ECO mode, measured in %.
- 99%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.9
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 2.5%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Potential-free outputIndicates whether the device provides a dry contact output that is electrically isolated from the internal power circuitry.
- Yes
- Auto shut-offIndicates whether the device automatically powers down after a period of inactivity to save energy.
- Yes
Other features
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- Fixed
- Output connection typeThe type of connection used for outputs from this device e.g. USB.
- Fixed
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 800 mm
- DepthThe distance from the front to the back of something.
- 990 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1987 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 408 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC/EN 62040-2 IEC/EN 62040-1 EN 62040-3
Packaging content
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Quick installation guideIndicates whether a simplified, fast-start manual is included with the product.
- Yes
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 0 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 0 min
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- No
Management features
- ECO modeIndicates whether the device features an energy-saving mode to reduce power consumption during operation.
- Yes
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 93PM G2 UPS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA
108000 W
Specs & where to buy

Eaton 93PM G2 UPS uninterruptible power supply (UPS) Double-conversion (Online) 300 kVA
270000 W
Specs & where to buy

Eaton 93PM G2 UPS uninterruptible power supply (UPS) Double-conversion (Online) 150 kVA
150000 W
Specs & where to buy

Eaton 93PM G2 UPS uninterruptible power supply (UPS) Double-conversion (Online) 300 kVA
270000 W
Specs & where to buy

Eaton 93PM G2 UPS uninterruptible power supply (UPS) Double-conversion (Online) 300 kVA
300000 W
Specs & where to buy

Eaton 93PM G2 UPS uninterruptible power supply (UPS) Double-conversion (Online) 360 kVA
324000 W
Specs & where to buy