Eaton 93E uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA 54000 W
- Form factor: Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 60 kVA
- Output power: 54000 W
- Operating temperature (T-T): 0 - 40 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The Eaton 93E UPS is designed to help IT managers address their biggest data center challenges: energy costs, remote management & space. Up to 35 percent smaller & 7 percent more effective than competitive units, the 93E provides an all-in-one, energy-efficient solution in the body of a compact UPS.
Lowest total cost of ownership
The 93E is up to seven percent more efficient than other UPSs in its class, helping to keep your operating costs down.
Guarantee zero downtime
Detachable maintenance bypass options allow you to redirect power during UPS service, preventing downtime and reducing repair time and costs.
Maximize runtime with batteries
Get the ability to scale as you grow with up to 21 minutes of runtime from internal batteries and up to 138 minutes of runtime when paired with an External Battery Cabinet (EBC).
Save floor space
The 93E occupies up to 35 percent less floor space than other UPSs in its class, giving you more room for revenue-producing equipment.
Documents
- ManualUser manual ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 60 kVA
- Output powerThe power that the device can produce.
- 54000 W
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 2000 m
- Display typeType of display (screen) e.g. LCD.
- LCD
Show all 36 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 60 kVA
- Output powerThe power that the device can produce.
- 54000 W
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 230 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 400 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 230 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 400 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 93.8%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 7%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 5%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 600 mm
- DepthThe distance from the front to the back of something.
- 800 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1880 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 202 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC/EN 62040-2 EN55022/EN55024 UL1778 ISO 9001: 2000, ISO 14001:1996 UL, cUL
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 2000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Charging currentThe amount of electrical current supplied during the charging process, measured in amperes (e.g., 2/6/12).
- 16 A
Ports & interfaces
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 65 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 93PS uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W

Eaton 93E uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA
27000 W

Eaton 93PS uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W

Eaton 93E20KMBSB uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA
18000 W

Eaton 93PS uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W

Eaton 93PS uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W