Eaton 93E uninterruptible power supply (UPS) Double-conversion (Online) 15 kVA 13500 W
- Form factor: Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 15 kVA
- Output power: 13500 W
- Bypass: Automatic on overload or UPS failure
All 40 specificationsProduct page at powerquality.eaton.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The Eaton 93E UPS delivers superior power protection for ever-expanding loads in today’s space-constrained data centres. Facilitating a lower total cost of ownership (TCO) through a combination of energy-efficiency, high reliability and a compact footprint the 93E is an ideal solution for small to medium - sized data centres and other applications desiring highly reliable power protection.
Documents
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 15 kVA
- Output powerThe power that the device can produce.
- 13500 W
- BypassSpecifies the method used to route power around the main circuitry to ensure continuous operation during maintenance or failure (e.g. Manual or Automatic).
- Automatic on overload or UPS failure
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1000 m
Show all 40 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Alarm
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 15 kVA
- Output powerThe power that the device can produce.
- 13500 W
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 220 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 415 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- 1%
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 98%
- Efficiency (On-line mode)The ratio of output power to input power when the device is operating in on-line mode, measured in %.
- 94%
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Overload capacity (10 minutes)The maximum percentage of the rated load that the unit can sustain for a duration of 10 minutes without failure, measured in %.
- 125%
- Overload capacity (1 minute)The maximum percentage of the rated load that the unit can sustain for a duration of one minute without failure, measured in %.
- 150%
- Total Harmonic Distortion (THD) (linear load)The percentage of harmonic distortion present in the output waveform when powered by a linear load, measured in %.
- 5%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Other features
- BypassSpecifies the method used to route power around the main circuitry to ensure continuous operation during maintenance or failure (e.g. Manual or Automatic).
- Automatic on overload or UPS failure
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 500 mm
- DepthThe distance from the front to the back of something.
- 710 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 960 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 72 kg
Safety regulation & standards
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- IEC 62040-1, IEC 62040-2, EMC Category C3, IEC 62040-3, ISO 9001:2000, ISO 14001:1996
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
Ports & interfaces
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.99
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 91PS-10(10)-1x9Ah-MBS uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W

Eaton 5PX2200IRTNBS uninterruptible power supply (UPS) Line-Interactive 2.2 kVA
1980 W 9 AC outlet(s)

Eaton 91PS-10(10)-0-MBS uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W

Eaton 9PX8KIRTNBP + 5Y Warranty uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA
7200 W 4 AC outlet(s)

Eaton 91PS-8(10)-1x9Ah-MBS uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA
8000 W

Eaton 9PX8KIRTNBP + 3Y Warranty uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA
7200 W 4 AC outlet(s)