Eaton 9135 UPS PPDM power distribution unit (PDU) 9 AC outlet(s) 3U
- AC outlets quantity: 9 AC outlet(s)
- Nominal input voltage: 208-240 V
- Nominal output voltage: 208-240 V
- Power plug: NEMA L6-30P
- AC outlet types: NEMA 5–15R, NEMA L6-20R
- Output connections: 1 x L6-20R, 8 x 5-15R
All 12 specificationsProduct page at powerquality.eaton.com ↗
Versions
NEMA 5–15R, NEMA L5-30R
NEMA 5–15R, NEMA L6-20R
NEMA 5–15R, NEMA L6-30R
NEMA 5–15R, NEMA L14-30R
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
PowerPass Distribution Modules (PPDMs) step down voltage to 120V to accommodate a variety of loads. The PPDM also provides a maintenance bypass, which allows you to replace the entire UPS without powering down the load.
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 9 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA L6-30P
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5–15R, NEMA L6-20R
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 442 mm
- DepthThe distance from the front to the back of something.
- 630 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 133 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 48.1 kg
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208-240 V
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208-240 V
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- 1 x L6-20R, 8 x 5-15R
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Basic
Features
- Rack capacityThe spase that device fill in rack.
- 3U
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 9135 UPS PPDM power distribution unit (PDU) 6 AC outlet(s) 3U
Specs & where to buy

Eaton 9130 Rackmount UPS PPDM power distribution unit (PDU) 7 AC outlet(s) 2U
Specs & where to buy

Eaton 9135 UPS PPDM power distribution unit (PDU) 3U
Specs & where to buy

Eaton ePBZ90 power distribution unit (PDU) 24 AC outlet(s) 0U Black
Specs & where to buy

Eaton 9130 Rackmount UPS PPDM power distribution unit (PDU) 7 AC outlet(s) 2U
Specs & where to buy

Eaton TPC2887-3121 power distribution unit (PDU) 8 AC outlet(s) 1U
Specs & where to buy