Eaton 5P1550RT2UNG2-L uninterruptible power supply (UPS) Line-Interactive 1.44 kVA 1350 W 10 AC outlet(s)
- Form factor: Rackmount
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 1.44 kVA
- Output power: 1350 W
- Rack mount kit
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Eaton 5P G2 1440VA 1350W 120V Line-Interactive UPS - 10 NEMA 5-15R Outlets, Lithium-Ion Battery, Pre-Installed Cybersecure Network Card, 2U Rack/Wall/Tower
Documents
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1.44 kVA
- Output powerThe power that the device can produce.
- 1350 W
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
Show all 49 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Steel
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1.44 kVA
- Output powerThe power that the device can produce.
- 1350 W
- Rack capacityThe spase that device fill in rack.
- 2U
- Cable lengthHow long the cable is.
- 1.8 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 89 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 162 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 100 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 125 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 95%
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.9
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 438 mm
- DepthThe distance from the front to the back of something.
- 360 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 85.5 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 14.1 kg
Packaging content
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 10 ms
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Lithium-Ion (Li-Ion)
- Battery voltageThe voltage (V) of the battery.
- 38.4 V
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 6.12 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 12.28 min
- Battery life (max)Maximum battery life. Mobile Mark (2002) is the standard often used to benchmark battery life time.
- 10 year(s)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 2 h
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- EBP-1605-L
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5-15R
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA 5-15P
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 10 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 12 A
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.9
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 40 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 5P550RG2-L uninterruptible power supply (UPS) Line-Interactive 0.55 kVA
495 W 6 AC outlet(s)
Specs & where to buy

Eaton 5P1000RT2UNG2-L uninterruptible power supply (UPS) Line-Interactive 1 kVA
920 W 10 AC outlet(s)
Specs & where to buy

Origin Storage 6/10kVA Symphony 9Ah Battery Extension Box For Use With SPY6KiRT(B)/ SPY10KiRT(B)
Specs & where to buy

Eaton 5P1000RT2UG2-L uninterruptible power supply (UPS) Line-Interactive 1 kVA
920 W 10 AC outlet(s)
Specs & where to buy

Origin Storage Uniti Power Symphony Online Double Conversion 230V 2U 1.5kVA / 1.5kW 4 x IEC C13
Specs & where to buy

Eaton 5P2200RTNG2 uninterruptible power supply (UPS) Line-Interactive 1.95 kVA
1950 W 6 AC outlet(s)
Specs & where to buy