DELL PowerStore 500T Storage server Rack (2U) 11.52 TB SSD Black
- Drive bays: 25, 2.5"
- Installed storage: 11.52 TB
- Type: Storage server, Rack (2U)
- Network: 25000 Mbit/s
All 46 specificationsProduct page at dell.com ↗
Versions
11.52 TB
19.2 TB
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
PowerStore All-Flash Storage
Intelligent platform accelerates block, file and vVols workloads while minimising manual effort. Energy-efficient, end-to-end NVMe design with multi-cloud backup integration.
Accelerate Zero Trust cybersecurity adoption
Advanced features support HWRoT, MFA, D@RE, ransomware protection, and more Built-in intelligence tunes resiliency without manual intervention STIG-hardened to meet the requirements of the US Federal Government
Simple, efficient backup and recovery
Manage multicloud and on-premises backup directly from PowerStore Incremental forever backups and end-to-end immutability Seamless user experience for your data centre, cloud, and edge environments
Achieve results faster with PowerStore
IDC study finds that PowerStore pays back investment in average of 11 months Participants achieved a 3-year ROI of 468% Conserve operational resources with 31% less staff time to deploy and 24% lower cost of operation
Documents
- DocumentEU Declaration of Conformity ↗
- DocumentDell PowerStore Open Source License and Copyright Information for GPLv3 and LGPLv3 ↗
- DocumentDell PowerStore Configuring Volumes ↗
- DocumentDell PowerStore Configuring SMB ↗
- DocumentDell PowerStore Setting Up PowerStore Manager ↗
- DocumentDell PowerStore Configuring NFS ↗
- DocumentDell PowerStore Alerts and Events Reference Guide ↗
- DocumentDell PowerStore Virtualization Infrastructure Guide ↗
- DocumentDell PowerStore Open Source License and Copyright Information ↗
- DocumentDell PowerStore Protecting Your Data ↗
Specifications
Key specifications
- Number of storage drives supportedHow many storage drives can be fit into the product at once.
- 25
- Storage drive sizes supportedThe sizes of storage drives that can be used with the product.
- 2.5"
- Total installed storage capacityThe combined maximum amount of data that can be stored across all installed drives, typically measured in terabytes (TB).
- 11.52 TB
- TypeCharacteristics of the device.
- Storage server
- Chassis typeThe type of rigid framework onto which is the hosuing for device components.
- Rack (2U)
- Ethernet LAN data ratesThe different speed levels of the Ethernet LAN connection.
- 25000 Mbit/s
Show all 46 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Storage server
Design
- Chassis typeThe type of rigid framework onto which is the hosuing for device components.
- Rack (2U)
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Network
- Ethernet LANAn Ethernet LAN (Local Area Network) interface is present, for a wired conection via a cable.
- Yes
- Ethernet LAN data ratesThe different speed levels of the Ethernet LAN connection.
- 25000 Mbit/s
- Copper ethernet cabling technologyThe specific standard used for data transmission over copper twisted-pair cables (e.g., 1000BASE-T).
- 2500BASE-T
Storage
- Storage drives installedStorage drives are built into the system.
- Yes
- Total installed storage capacityThe combined maximum amount of data that can be stored across all installed drives, typically measured in terabytes (TB).
- 11.52 TB
- Number of storage drives installedAmount of storage drives built into the device.
- 6
- Number of storage drives supportedHow many storage drives can be fit into the product at once.
- 25
- Installed storage drive typeType of storage drives built into the device e.g. HDD (hard disk drive), SSD (solid-state drive).
- SSD
- Supported storage drive typesThe type of storage drives the device is compatible with.
- HDD & SSD
- Storage drive capacityThe amount of data that can be stored on the storage drive.
- 1.92 TB
- Storage drive sizeThe size of the storage drive, given in inches ('').
- 2.5"
- Storage drive sizes supportedThe sizes of storage drives that can be used with the product.
- 2.5"
- NVMeNVM Express (NVMe) or Non-Volatile Memory Host Controller Interface Specification (NVMHCIS) is an open logical device interface specification for accessing non-volatile storage media attached via a PCI Express (PCIe) bus. NVM Express, as a logical device interface, has been designed to capitalize on the low latency and internal parallelism of solid-state storage devices.
- Yes
- Maximum supported storage capacityThe maximum capacity of data storage on the device.
- 6297.6 TB
- RAID supportThe device uses RAID, which is a storage technology that combines multiple disk drive components into a logical unit for the purposes of data redundancy and performance improvement. Data is distributed across the drives in one of several ways, referred to as RAID levels, depending on the specific level of redundancy and performance required.
- No
- Number of drives (max)The maximum number of storage drives that can be installed in the device.
- 97
- Mezzanine cardIndicates whether the device supports the installation of a mezzanine card for expanded connectivity or functionality.
- Yes
- Quantity of mezzanine cards (max)The maximum number of mezzanine cards that can be installed in the device.
- 2
Other features
- I/O portsAn interface on a device to which you can connect another device.
- 16GB FC 4 Port IO Module Pair (SFPs included)
Packaging content
- Packaging contentA list of all items and documentation included in the box (e.g. Quick Start Guide).
- PowerStore Field Install Kit C20/C19, C20/C13, C14/C13 pairs
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 447.2 mm
- DepthThe distance from the front to the back of something.
- 795.5 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 87.2 mm
- Weight (empty)The mass of the device when no drives or additional components are installed, measured in g.
- 30.4 kg
Power
- Power supply locationWhere the power supply is positioned.
- Built-in
- Power supply unit (PSU) capacityThe maximum power output that the power supply can provide to the system, typically measured in watts (W).
- 1450 W
- Number of power supply unitsThe total quantity of power supply modules integrated into or provided with the device.
- 2
- Redundant power supply (RPS) supportAdditional power supply which can run a computer if the main power supply fails.
- Yes
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 200 - 240 V
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Power cable connector 1The type of electrical interface used for the first power connection, such as a C13 or C14 coupler.
- C13 coupler
- Power cable connector 2The type of electrical interface used for the second power connection, such as a C13 or C14 coupler.
- C14 coupler
Software
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- PowerStore Base SW
Performance
- Device classThe category to which this device belongs.
- Large Enterprise Business
- Backup functionThe function if the main power source fails.
- Yes
- Management protocolsThe communication standards used for the remote administration and monitoring of the device (e.g. LoRaWAN).
- FC, NVMe/FC, iSCSI, NVMe/TCP,NFSv3, NFSv4, NFSv4.1; CIFS (SMB 1), SMB 2, SMB 3.0, SMB 3.02, and SMB 3.1.1; FTP and SFTP
- Fiber optic connectorThis terminates the end of an optical fiber, and enables quicker connection and disconnection than splicing. The connectors mechanically couple and align the cores of fibers so light can pass. Better connectors lose very little light due to reflection or misalignment of the fibers. In all there have been about 100 types of optic fiber connectors produced.
- SFP
Ports & interfaces
- Fiber ports quantityThe number of sockets (ports) for fibers (cables).
- 4
Memory
- Maximum RAM supportedThe highest amount of random access memory that can be installed in the device, measured in gigabytes (GB) or terabytes (TB).
- 192 GB
- Memory form factorDesign of the memory e.g. 240-pin DIMM, SO-DIMM.
- DIMM
Processor
- Processor manufacturerThe manufacturer that produced the processor.
- Intel
- Processor frequencyThe clock rate is the fundamental rate in cycles per second (measured in hertz) at which a computer performs its most basic operations such as adding two numbers. There are more factors, like internal memory size, that influence a computer's actual response time.
- 2.2 GHz
- Processor coresThe number of central processing units ('cores') in a processor. Some processors have 1 core, others have 2 (e.g. Intel Core Duo) or more (e.g. the Intel Xeon E7-2850 has 10 cores).
- 24
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

DELL PowerStore 1200T Storage server Rack (2U)
Intel Xeon 19.2 TB SSD Black

DELL UNITY 480 Storage server Rack (2U)
6 TB SSD Black

DELL PowerProtect DP4400 Storage server Rack (2U)
12 TB HDD Black

DELL Unity XT 480 Storage server Rack (2U)
14 TB HDD+SSD Black

DELL PowerProtect DM5500 Storage server Rack (2U)
24 TB HDD Black

DELL Unity XT 380 Storage server Rack (2U)
14 TB HDD+SSD Black