DELL Online Rack UPS 5600W uninterruptible power supply (UPS) 10 AC outlet(s)
- Form factor: Rackmount
- Product colour: Black
- Output power: 5600 W
- Nominal output voltage: 230 V
- Nominal input voltage: 220-240 V
- Operating temperature (T-T): 32 - 104 °F
All 35 specificationsProduct page at accessories.euro.dell.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The new Dell UPS provide reliable, vital power backup of IT equipment while simplifying UPS selection, installation, and monitoring processes. Enables easier and faster UPS deployment with first UPS line to offer tool-less Ready Rails rack-mounting .Cuts energy usage and cost with first comprehensive line built to run at 95 to 98% efficiency. Provides more local information with only UPS to feature same rich graphical multi-language LCD display as Dell servers. Simplifies UPS selection process with first leading UPS provider to rate UPS models by Wattage only. Simplifies UPS management with downloadable flash upgrades and UPS management software. This product has been tested and validated on Dell systems. It is supported by Dell Technical Support when used with a Dell system.
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Output powerThe power that the device can produce.
- 5600 W
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 220-240 V
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 32 - 104 °F
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- UL, CSA, IEC, EN
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 60 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
Show all 35 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
Features
- Output powerThe power that the device can produce.
- 5600 W
- Rack capacityThe spase that device fill in rack.
- 4U
- CompatibilityThe other products, software and hardware this product can be used with.
- PowerEdge 2950/2970 FS / R200 /R300 Rack / R805 FS / R710 Rack / T710 FS / R210 FS / R900 FS / R905 FS / T710 FS / R210 FS PowerEdge Rack Black-Direct Ship / 2970 ENERGY SMART FS
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 220 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 240 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 216 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 216 V
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 96%
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 220-240 V
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 30 A
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 32 - 104 °F
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 60 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 438 mm
- DepthThe distance from the front to the back of something.
- 801.4 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 171.5 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 72 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL, cUL, CE, GS, GOST, BSMI, S-MARK, KC, NRCS, C-tick, CQC, IEC, EN, CISPR, FCC, CNS, AS/NZS, KN, GB
Safety regulation & standards
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- UL, CSA, IEC, EN
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 5.5 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 17 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 4 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 10 AC outlet(s)
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

DELL PowerEdge Tower
1000W uninterruptible power supply (UPS) 8 AC outlet(s)

DELL Rack UPS
5600W uninterruptible power supply (UPS)

DELL PowerEdge
500W uninterruptible power supply (UPS) 6 AC outlet(s)

DELL 450-14145 uninterruptible power supply (UPS) 2.4 kVA
1920 W 2 AC outlet(s)

DELL PowerEdge 210-38756 uninterruptible power supply (UPS)
3750 W 10 AC outlet(s)

DELL 450-14149 uninterruptible power supply (UPS) 1.5 kVA
4200 W