DELL A6783202 power distribution unit (PDU) 24 AC outlet(s) 0U Black
- AC outlets quantity: 24 AC outlet(s)
- Cables included: AC, Serial
- Operating temperature (T-T): -5 - 45 °C
- Operating relative humidity (H-H): 5 - 95%
- Nominal input voltage: 400 V
- AC input frequency: 50 - 60 Hz
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
APC metered-by-outlet rack power Distribution Unit (PDU) provides active metering of individual outlets to enable energy optimization and detailed capacity planning. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered-by-outlet rack PDU provides a more granular level of power utilization data to allow data center managers to make more precise decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered-by-outlet rack PDU includes individual outlet power metering, a temperature/humidity sensor port, and locking IEC receptacles.
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 24 AC outlet(s)
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- AC, Serial
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 400 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
- Output voltageThe electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48).
- 230 V
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Voltage
- Management protocolsThe communication standards used for the remote administration and monitoring of the device (e.g. LoRaWAN).
- SNMP, Telnet, HTTP, HTTPS, SSH, CLI
Show all 30 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 24 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- IEC 60309
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 1
- USB ports quantityThe total number of available Universal Serial Bus (USB) connection interfaces on the device.
- 1
Packaging content
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- AC, Serial
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 56 mm
- DepthThe distance from the front to the back of something.
- 51 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1829 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 8.23 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 400 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
Features
- Output voltageThe electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48).
- 230 V
- Cable lengthHow long the cable is.
- 1.83 m
- TypeCharacteristics of the device.
- Three-phase
- Rack capacityThe spase that device fill in rack.
- 0U
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Voltage
- Firmware upgradeableIndicates whether the internal software of the device can be updated to a newer version to improve performance or add features.
- Yes
Performance
- Management protocolsThe communication standards used for the remote administration and monitoring of the device (e.g. LoRaWAN).
- SNMP, Telnet, HTTP, HTTPS, SSH, CLI
Other features
- Compatible productsOther products that can be used with this product.
- AR3100, AR3150, SMX3000RMHV2UNC
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered, Switched
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Display
- DisplayThe description of display that can includes display type, resolution, size etc.
- LED
Packaging data
- Package weightWeight of the packaged product.
- 10.5 kg
- Package widthThe distance from one side of the packaging to the other.
- 162 mm
- Package depthThe distance from the front to the back of the packaging.
- 117 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 2038 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

DELL A7067475 power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black

DELL A7067536 power distribution unit (PDU) 20 AC outlet(s) 0U Black

DELL AB555865 power distribution unit (PDU) 24 AC outlet(s) 0U Black

DELL A7067512 power distribution unit (PDU) 15 AC outlet(s) 0U Black

DELL AB515460 power distribution unit (PDU) 24 AC outlet(s) 0U Black