
D-Link DXS-3610-54S network switch Managed L3 1U Black
- Rack mounting
- Stackable
- MAC address table: 288000 entries
- Switch type: Managed
- Operating temperature (T-T): 0 - 45 °C
- Storage temperature (T-T): -40 - 70 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
OpenFlow Switching that Stacks Above the Competition
The DXS-3610 Layer 3 Stackable 10G/100G Managed OpenFlow Switches are compatible with SDN-enabled network architecture for deployment in high-performance datacenter, enterprise, and campus applications. Hot-swappable PSU and fan modules with load sharing capabilities significantly reduce network downtime and power consumption. Stackable up to 12 units and high port density makes the DXS-3610 the ideal choice for future-proofing your aggregation/core network.
High Availability
The DXS-3610 Series boasts high-performance 10G Ethernet switching capacity of up to 2.16 Tbps with forwarding rates of up to 1607 Mpps.
Hot-Swappable Redundancy
The DXS-3610 Series also features a modular fan back-up design, providing n+1 redundancy for the system. The modular power design allows either AC or DC power sources for maximum deployment flexibility. With dual power modules, the power load is distributed, extending the lifetime of the modules.
Robust and Versatile Stacking Capability
Stack up to 12 DXS-3610 switches with up to a total of 1200G (1.2T) stacking bandwidth. Perfect for small to medium-sized data centers in enterprise or campus applications using leaf-spine or top-of-rack (ToR) architecture.
Simplified Deployment
Remotely activate the front panel LED indicator to rapidly locate the DXS-3610 in your data center or server room that requires extra attention.
Enhanced Manageability for Peace of Mind
For more complex network infrastructures, D-View 7, a centralized management platform, can be installed for in-depth network management and maintenance to optimize network availability, reliability, security, and resilience.
Documents
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Rack mountingThe type of mounting that can position devices in a shelving system (rack).
- Yes
- StackableDevices can be placed on top of each other.
- Yes
- MAC address tableThe MAC address is the 'Media Access Control Address'. It is a unique address given to a network interface controller (NIC) in a device. A MAC address table shows the addresses in a table format.
- 288000 entries
- Switch typeWhat switch device has, managed or unmanaged.
- Managed
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -40 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Heat dissipationThe heat generated by the power supply.
- 1083 BTU/h
- Redundant power supply (RPS) supportAdditional power supply which can run a computer if the main power supply fails.
- Yes
Show all 58 specificationsShow key specifications only
Design
- Rack mountingThe type of mounting that can position devices in a shelving system (rack).
- Yes
- StackableDevices can be placed on top of each other.
- Yes
- Form factorThe shape or design of the product.
- 1U
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Number of fansThe quantity of fans (apparatus with rotating blades that creates a current of air for cooling or ventilation).
- 5 fan(s)
Data transmission
- MAC address tableThe MAC address is the 'Media Access Control Address'. It is a unique address given to a network interface controller (NIC) in a device. A MAC address table shows the addresses in a table format.
- 288000 entries
- Switching capacityThe data transfer capacity of the switch per second.
- 2160 Gbit/s
- Forwarding rateThe number of packets the device can process and send per second, measured in millions of packets per second (e.g., 148.8 Mpps).
- 1607.04 Mpps
- Static routeIndicates whether the device allows the manual configuration of fixed paths for network traffic to specific destinations.
- Yes
- Jumbo framesIndicates the support for Ethernet frames larger than the standard 1500 bytes to increase data transfer efficiency (e.g. 9000 bytes).
- 9436
- Packet buffer memoryThe amount of memory available in the network switch to temporarily store data packets during congestion, typically measured in megabytes (MB) or kilobytes (KB).
- 32 MB
Ports & interfaces
- Basic switching RJ-45 Ethernet ports typeThe type/category of basic switching RJ-45 Ethernet ports (sockets).
- No
- SFP+ module slots quantityThe total number of available slots for inserting SFP+ transceiver modules to provide high-speed fiber optic or copper connectivity.
- 48
- QSFP+ module slots quantityThe total number of available slots for inserting QSFP+ transceiver modules.
- 6
- Console portThe type of physical connector used for the management or console interface of the device (e.g. RJ-45 or USB).
- RJ-45
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
Management features
- Switch typeWhat switch device has, managed or unmanaged.
- Managed
- Switch layerA network switch is a computer networking device that links networking segments. A switch has different layers, such as layer 2 (a network bridge, operating at the data link layer, interconnecting a small number of devices) and layer 4 (can act as a firewall, amongst other things).
- L3
- Quality of Service (QoS) supportIndicates whether the device supports Quality of Service (QoS) to prioritize specific network traffic to ensure performance for critical applications.
- Yes
- ARP inspectionIndicates whether the device supports Dynamic ARP Inspection to prevent ARP spoofing attacks by validating Address Resolution Protocol packets.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 441 mm
- DepthThe distance from the front to the back of something.
- 487.4 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 43.5 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 9.8 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -40 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Heat dissipationThe heat generated by the power supply.
- 1083 BTU/h
Power
- Redundant power supply (RPS) supportAdditional power supply which can run a computer if the main power supply fails.
- Yes
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 100 - 240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Power consumption (typical)Amount of power consumed by this model, often expressed in watts (W). Typical values that manufacturers give are power consumption when off, standby/suspended mode, typical use, maximum usage.
- 120.6 W
- Power consumption (max)The maximum amount of power used by the device.
- 320.8 W
Performance
- Virtual stacking (units)The maximum number of physical devices that can be logically grouped together to be managed as a single entity.
- 32
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 79.4 dB
- Access Control List (ACL)Indicates whether the device supports the definition of rules to filter network traffic and manage access permissions based on specific criteria.
- Yes
- Web-based managementUsing a website/web application to manage something.
- Yes
Features
- Mean time between failures (MTBF)Statistical model used to indicate product/mechanism reliability; expressed in hours and percentage of duty cycle. This number (in hours) does not indicate the mean time before failure for a single unit/mechanism.
- 94262 h
- Full duplexA full-duplex system allows communication in both directions, and unlike half-duplex, allows this to happen simultaneously.
- Yes
Multicast features
- Multicast supportIndicates whether the device supports the simultaneous transmission of a single data stream to multiple recipients.
- Yes
Security
- IGMP snoopingIndicates whether the device can optimize multicast traffic by ensuring it is only forwarded to the ports that have requested it.
- Yes
- MAC address filteringSecurity access control method whereby the 48-bit address assigned to each network card is used to determine access to the network. MAC addresses are uniquely assigned to each card, so using MAC filtering on a network permits and denies network access to specific devices through the use of blacklists and whitelists.
- Yes
- SSH/SSL supportIndicates whether the device supports secure remote management via SSH or SSL protocols.
- Yes
- BPDU filtering/protectionIndicates whether the device supports Bridge Protocol Data Unit (BPDU) filtering or protection to prevent network loops and enhance security.
- Yes
- Queue scheduling algorithmsThe method used by the device to manage the order in which data packets are transmitted from the output buffer, such as Priority Queuing (PQ) or Deficit Round Robin (DRR).
- Weighted Round Robin (WRR)
Network
- Jumbo frames supportIndicates whether the device supports Ethernet frames with a payload larger than the standard 1500 bytes to increase data transfer efficiency.
- Yes
- Networking standardsThe way in which the network is working, e.g. IEEE 802.11a, IEEE 802.11b, IEEE 802.11g.
- IEEE 802.1D, IEEE 802.1s, IEEE 802.1w
- 10G supportThe product can use Oracle 10G, which is a database management system introduced in 2003.
- Yes
- Port mirroringIndicates whether the network switch can copy traffic from one or more ports to another port for monitoring and analysis purposes.
- Yes
- IP routingIndicates whether the device can forward data packets between different networks by determining the best path to the destination.
- Yes
- Half duplexIndicates whether the device supports half-duplex communication, where data can be sent or received but not both simultaneously.
- Yes
- Flow control supportIndicates whether the device supports the management of data transmission rates to prevent buffer overflow.
- Yes
- Link aggregationIndicates whether the device supports combining multiple network connections into a single logical link to increase throughput and provide redundancy.
- Yes
- Spanning tree protocolIndicates whether the device supports a network protocol that prevents loops in a bridge network topology.
- Yes
- Head-of-line (HOL) blockingIndicates whether the device is susceptible to a performance degradation where a queue is blocked by a packet at the front of the line.
- Yes
- VLAN supportA Virtual Local Area Network (VLAN) consists of a group of computers and switches that can be physically distributed over different networks and buildings, but form one LAN on a logical level.
- Yes
- Virtual LAN featuresSpecifies the supported methods for segmenting a network into multiple logical broadcast domains on the switch or access point (e.g., MAC address-based VLAN or Management VLAN).
- MAC address-based VLAN, Port-based VLAN, Protocol-based VLAN
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

D-Link 48-Port Gigabit Stackable POE+ Smart Managed Switch with 2 x 10GBase-T & 2 x 10G SFP+

D-Link 26-Port PoE+ Gigabit Smart Managed Switch

D-Link 48-Port Gigabit Stackable Smart Managed Switch with 2 x 10GBase-T Ports & 2 x 10G SFP+

D-Link DGS-1100-18PV2 network switch Managed L2 Gigabit Ethernet
(10/100/1000) Power over Ethernet (PoE) 1U Black

D-Link 28-Port Gigabit Stackable POE+ Smart Managed Switch with 2 x 10GBase-T & 2 x 10G SFP+

D-Link DGS-1100-10MPV2 network switch Managed L2 Gigabit Ethernet
(10/100/1000) Power over Ethernet (PoE) 1U Black