CyberPower UT650EIG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA 360 W 4 AC outlet(s)
- Form factor: Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 0.65 kVA
- Output power: 360 W
- Compliance certificates: CE, RoHS
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
CyberPower UT650EIG guarantees power protection for computers, networking equipment, and storage devices. The product adopts line-interactive topology with Automatic Voltage Regulation (AVR) function to offer stabilized AC power output. The patented GreenPower UPS Bypass design achieves ultra-low power consumption to reduce energy costs, and allows a lower operation temperature which extends battery lifespan.
The LED indicator shows the utility, battery and operating status of the UPS. It is also compatible with generators to extend power continuity. Other features include overload protection, EMI filter and configurable alarm to safeguard your devices. Its tower design allows users to place it easily on desks or other tight spaces.
Videos & documents
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.65 kVA
- Output powerThe power that the device can produce.
- 360 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Power load cable
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 50 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Show all 45 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Plastic
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Power
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.65 kVA
- Output powerThe power that the device can produce.
- 360 W
- Cable lengthHow long the cable is.
- 1.2 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 165 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 290 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (max)The maximum output voltage produced by the device.
- 230 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- 1%
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 125 J
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Fault, Low battery alarm, Overload alarm
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 84 mm
- DepthThe distance from the front to the back of something.
- 280 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 174 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 3.8 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
Packaging content
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Power load cable
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 50 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 90%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 3000 m
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 6 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- IEC 320
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C13 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 2.83 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Display
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 4 ms
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 109 mm
- Package depthThe distance from the front to the back of the packaging.
- 315 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 229 mm
- Package weightWeight of the packaged product.
- 4.05 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OLS6000ERTXL3U uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
5400 W 1 AC outlet(s)

CyberPower EC450G uninterruptible power supply (UPS) Standby (Offline) 0.45 kVA
260 W 8 AC outlet(s)

CyberPower PR3000RTXL2UN uninterruptible power supply (UPS) Line-Interactive 3 kVA
3000 W 9 AC outlet(s)

CyberPower PR3000RTXL2U uninterruptible power supply (UPS) Line-Interactive 2.7 kVA
2700 W 9 AC outlet(s)

CyberPower PR2200RTXL2UN uninterruptible power supply (UPS) Line-Interactive 2.2 kVA
2200 W 8 AC outlet(s)

CyberPower PR2200RT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA
2200 W 8 AC outlet(s)