CyberPower SM020KAMFA uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA 20000 W
- Form factor: Rackmount
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 20 kVA
- Output power: 20000 W
- Rack mount kit
All 49 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The CyberPower SM020KAMFA Smart App Online 3-Phase Modular UPS System brings flexibility, space savings, and efficiency to 3-Phase power protection technology. Configurable for N+N system or N+1 power module redundancy, the system can intelligently manage individual modules to achieve higher efficiency. The customizable modular design can be configured as a tower, side-by-side, or integrated within a rack. The high-density, scalable 10kVA/10kW power modules are 2U in height, saving space while providing more options for capacity expansion.
The SM020KAMFA features double-conversion topology for seamless power protection and a pre-installed RMCARD205 for remote management. The user-friendly 7” color touchscreen displays key status indicators at-a-glance. Three-stage Smart Battery Management (SBM) equalizes battery voltages and reduces excessive heat to extend battery life. Plus, hot-swappable power modules, battery and, bypass allow for rapid replacement and minimal impact to system operation. Ideal for high-end data centers, the SM020KAMFA Smart App Online 3-Phase Modular UPS System assures reliable, high-quality AC power and includes a One-Year Limited Warranty.
Double-Conversion Topology
Provides consistent, clean, and nearly perfect power, regardless of the condition of the incoming power. Never a need to switch to battery as DC power operates 100% of the time. Designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave Output
Keeps sensitive equipment with Active PFC working by preventing unnecessary shutdowns caused by gaps from simulated sine waves.
Full Matrix LCD Touch Screen
Simple to set up, the user-friendly 7” color touchscreen display provides key status indicators at-a-glance with alerts of potential problems that could impact equipment and cause downtime. Screen tilts up to 22 degrees for easy viewing.
Hot-Swappable Batteries
Keeps equipment running by eliminating downtime during UPS power maintenance.
N+N Redundancy
Ensures uninterrupted operation if the entire system fails. N+1 redundancy guarantees system availability if one power module fails.
Expandable External Battery Cabinet
Extends runtime by adding space for additional battery modules.
Smart Battery Mangement
Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
Battery Equalization Technology
Battery Equalization is an advanced charging process that maintains the voltages of the batteries at the same level to increase battery life.
PowerPanel Business Software
Provides tools for easy remote monitoring and managing of the UPS and automates shutdown of multiple devices when needed.
RMCARD205
Enables remote management of up to 50 clients via a standard web browser, command-line interface (CLI), or network management system (NMS) connection.
Optional Input and Output 175A Circuit Breakers
Ensures power is turned off during service or maintenance and eliminates the risk of unintended powering off.
Upgradable UPS Firmware
Keeps equipment running by eliminating downtime during UPS power maintenance.
Multiple Language Options
The LCD Control Panel can be configured in English or Chinese.
Emergency Power Off (EPO)
Allows the UPS to be shut off in the event of an emergency when the EPO port is connected to an EPO switch.
Generator Compatible
Ensures a stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
Converter Mode
Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.
USB, Serial, Modbus, and SNMP Connectivity
Flexible connectivity to use PowerPanel software, Modbus, or an RMCARD205 to monitor and manage your Smart App Online 3-Phase Modular UPS.
Audible Alarms
Identifies when the UPS is running on battery power, overloaded, or has a low battery.
Customizable Configuration
The customizable modular design can be configured as a tower, side-by-side, or integrated within a rack.
Documents
- BrochureProduct Brochure ↗
- DocumentInstallation Manual ↗
- DocumentOperators Manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 20 kVA
- Output powerThe power that the device can produce.
- 20000 W
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Show all 49 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Metal
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Status
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 20 kVA
- Output powerThe power that the device can produce.
- 20000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 120 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 220 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 120 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 220 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 92.5%
- Efficiency (On-line mode)The ratio of output power to input power when the device is operating in on-line mode, measured in %.
- 93%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 1
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 1.5%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 6%
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 485 mm
- DepthThe distance from the front to the back of something.
- 775 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 607 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 60.7 kg
Packaging content
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 1000 - 3048 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- 6
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Hardwire
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232, RS-485
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 2
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 56 dB
Power
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 632 mm
- Package depthThe distance from the front to the back of the packaging.
- 1022.4 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 787.4 mm
- Package weightWeight of the packaged product.
- 92 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OLS3000EA-DE uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2700 W 7 AC outlet(s)

CyberPower UT1200EIG uninterruptible power supply (UPS) Line-Interactive 1.2 kVA
700 W 6 AC outlet(s)

CyberPower SX650U uninterruptible power supply (UPS) Standby (Offline) 650 kVA
360 W 8 AC outlet(s)

CyberPower OLS2000EA-DE uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA
1800 W 4 AC outlet(s)
CyberPower CP825AVRLCDa uninterruptible power supply (UPS)

CyberPower OLS1500EA uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA
1350 W 4 AC outlet(s)