CyberPower PR750ELCDGR uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 675 W 4 AC outlet(s)
- Form factor: Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 0.75 kVA
- Output power: 675 W
- Battery type: RBP0014
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
CyberPower PR750ELCDGR Line-Interactive UPS, with seamless Pure Sine Wave, provides the best power protection available for office system devices including PCs, workstations, networking devices, and peripherals. It’s typically integrated in the back office, server room, and data center environment.
The UPS can be locally managed via USB or serial ports, or remotely managed via an SNMP Card (an optional Remote Management Card), allowing administrators and users unsurpassed flexibility to remotely access each UPS through the network to perform real-time monitoring, UPS configurations, and scheduled system shutdowns by using PowerPanel Management software.
Videos & documents
- VideoCyberPower UPS Management Introduction ↗
- BrochureProduct Brochure ↗
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.75 kVA
- Output powerThe power that the device can produce.
- 675 W
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- RBP0014
- Warranty periodThe length of time the manufacturer guarantees the product against defects, typically expressed in months or years.
- 3 year(s)
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Sustainability complianceIndicates whether the product complies with established environmental and sustainability standards.
- Yes
Show all 64 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Metal
- Control typeThe way in which the device is controlled.
- Buttons
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Battery replacement, Fault, Power
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.75 kVA
- Output powerThe power that the device can produce.
- 675 W
- Country of originCountry where the device is made. Aka Country of manufacture (COM).
- China
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 150 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 301 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 230 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 230 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 405 J
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 1
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 1
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.9
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Fault, Low battery alarm
Power
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- RBP0014
- Number of batteries supportedThe number of batteries that can be used with the product.
- 1
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Other features
- Warranty periodThe length of time the manufacturer guarantees the product against defects, typically expressed in months or years.
- 3 year(s)
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 136 mm
- DepthThe distance from the front to the back of something.
- 349 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 162 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 12.3 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
Packaging content
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Sustainability
- Sustainability complianceIndicates whether the product complies with established environmental and sustainability standards.
- Yes
- Sustainability certificatesThe environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).
- ENERGY STAR
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
- Heat dissipationThe heat generated by the power supply.
- 75 BTU/h
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 4 ms
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 2.5 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 10.5 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, Type F
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C14 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type-B
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
Performance
- Management protocolsThe communication standards used for the remote administration and monitoring of the device (e.g. LoRaWAN).
- SNMP/HTTP
Logistics data
- Harmonized System (HS) codeThe standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.
- 8504408590
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 272 mm
- Package depthThe distance from the front to the back of the packaging.
- 486 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 283 mm
- Package weightWeight of the packaged product.
- 13.3 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower RT33010KEN uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W

CyberPower UT1050EIG uninterruptible power supply (UPS) Line-Interactive 1.05 kVA
630 W 6 AC outlet(s)
CyberPower PR3000RTXL2UHVA uninterruptible power supply (UPS)

CyberPower LX1100G uninterruptible power supply (UPS) Line-Interactive 1.1 kVA
660 W 10 AC outlet(s)

CyberPower OLS1000EA uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA
900 W 3 AC outlet(s)

CyberPower LX1500GU uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
900 W 10 AC outlet(s)