CyberPower PR2200ERTXL2UAC uninterruptible power supply (UPS) Line-Interactive 2.2 kVA 2200 W 10 AC outlet(s)
- Form factor: Rackmount/Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 2.2 kVA
- Output power: 2200 W
- Battery type: RBP0130
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
CyberPower PR2200ERTXL2UAC with rackmount design guarantees power backup protection for home theater systems, multimedia devices, IT equipment, computers, workstations, NAS/Storage devices, telecom devices, networking devices, and surveillance systems. The UPS adopts line-interactive topology with Automatic Voltage Regulation (AVR) function, and offers stabilized Pure Sine Wave output to ensure high power quality.
The UPS’s output power factor is 1, which means it is capable of connecting to more critical loads than conventional UPS. It also features Battery Management Technology to help batteries obtain optimal life span by balancing battery string voltage. The quick charging technology allows fast and safe battery charging. Its multi-functional matrix LCD supports intuitive operation and quick configuration. The LCD panel is also rotatable to meet installation requirements.
Videos & documents
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 2.2 kVA
- Output powerThe power that the device can produce.
- 2200 W
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- RBP0130
- Batteries includedIndicates whether the required batteries are supplied with the product.
- Yes
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Serial
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Show all 80 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Metal
- Extended battery module rack capacityThe amount of vertical space the battery module occupies in a standard equipment rack, expressed in rack units (e.g., 2U).
- 2U
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- Built-in fanIndicates whether the product has an integrated fan for active cooling.
- Yes
- Control typeThe way in which the device is controlled.
- Buttons
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 2.2 kVA
- Output powerThe power that the device can produce.
- 2200 W
- Country of originCountry where the device is made. Aka Country of manufacture (COM).
- China
- Rack capacityThe spase that device fill in rack.
- 2U
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 148 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 288 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Output frequency regulationThe range or precision within which the output frequency can be adjusted or maintained, measured in Hz.
- 1 Hz
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- 5%
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 2430 J
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 1
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 1
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Fault, Low battery alarm, Overload alarm
- Detachable power cordIndicates whether the power cable can be removed from the soundbar for easier transport or replacement.
- Yes
Power
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- RBP0130
- Number of batteries supportedThe number of batteries that can be used with the product.
- 1
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
- Power Factor Correction (PFC) typeSpecifies the method used by the power supply unit to improve the efficiency of power delivery and reduce harmonic distortion, such as Active or Passive PFC.
- Active
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
- Power source typeWhat the power source is.
- AC
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 630 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 86.5 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 42 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, Federal Communications Commission (FCC), RCM, RoHS, UL, VCCI
Packaging content
- Batteries includedIndicates whether the required batteries are supplied with the product.
- Yes
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Serial
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Sustainability
- Sustainability complianceIndicates whether the product complies with established environmental and sustainability standards.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
- Heat dissipationThe heat generated by the power supply.
- 135 BTU/h
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 6 ms
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 5.6 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 16 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 3 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- BP48VP2U03
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C20 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 10 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type-B
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 2
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 2
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 575 mm
- Package depthThe distance from the front to the back of the packaging.
- 765 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 275 mm
- Package weightWeight of the packaged product.
- 50.2 kg
- Package typeThe type of product package e.g. box.
- Box
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower PR3000ERTXL2UAC uninterruptible power supply (UPS) Line-Interactive 3 kVA
300 W 10 AC outlet(s)

CyberPower LCD Line-Interactive USV 650VA/360WLCD, AVR, USB, Outlets
(3) Schuko

CyberPower PFC Sinewave uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
900 W 6 AC outlet(s)

CyberPower LCD OLS6KERT5U-NEMA uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
6000 W 4 AC outlet(s)

CyberPower PFC Sinewave uninterruptible power supply (UPS) Line-Interactive 0.5 kVA
300 W 6 AC outlet(s)

CyberPower OL5KERTHDL uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA
5000 W 10 AC outlet(s)