CyberPower PDU44006 power distribution unit (PDU) 10 AC outlet(s) 1U Black
- AC outlets quantity: 10 AC outlet(s)
- Operating temperature (T-T): 0 - 45 °C
- Storage temperature (T-T): -15 - 55 °C
- Operating relative humidity (H-H): 0 - 95%
- Operating altitude: 0 - 4000 m
- Non-operating altitude: 0 - 14999 m
All 38 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Product Overview
Ensure continued operation of critical devices with the CyberPower PDU44006 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management.
The PDU44006 supports inputs between 200-240V and includes (8) IEC C13 and (2) IEC C19 outlets. Dual NEMA L6-20P power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications.
Power Distribution
Delivers AC power to servers, equipment, and connected devices via a power distribution unit.
Switch-free Design
Safeguards against accidental power shut down.
Mounting Brackets
Includes all necessary hardware for horizontal rack installation.
Long Input Power Cord
Reaches distant power sources, allowing the PDU to be placed where it’s needed.
Cord Retention Brackets
Secures power cords, keeping them organized and accessible. Helps cords stay plugged in.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
- ManualUser manual ↗
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 10 AC outlet(s)
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 4000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 14999 m
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL62368 FCC Class A cTUVus
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 240–200 VAC
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50–60
Show all 38 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 10 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA L6-20P
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 1
- USB ports quantityThe total number of available Universal Serial Bus (USB) connection interfaces on the device.
- 1
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 215 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 44 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 3.76 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 4000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 14999 m
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL62368 FCC Class A cTUVus
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 240–200 VAC
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50–60
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 20 A
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 20 A
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 240–200 VAC
Features
- Output voltageThe electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48).
- 240–200 VAC
- Cable lengthHow long the cable is.
- 3 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 1U
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Current, Power, Voltage
Network
- Supported network protocolsNetwork protocols tested as compatible with this product e.g. FTP,HTML, POP.
- IPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMTP, FTP, IPv6, SNMPv3, HTTPs, SSH, SSL, TLS, LDAP(S), RADIUS, Syslog, CLI, Windows AD
Design
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Status, Selected, TX / RX, Link
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Switched, Monitored
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal
- Housing materialWhat the casing of the product is made of.
- Metal
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Display
- DisplayThe description of display that can includes display type, resolution, size etc.
- LCD
Performance
- On/off switchThe button which is pressed to switch the device on or off.
- No
Packaging data
- Package weightWeight of the packaged product.
- 6.58 kg
- Package widthThe distance from one side of the packaging to the other.
- 549.9 mm
- Package depthThe distance from the front to the back of the packaging.
- 398 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 124.5 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower PDU24007 power distribution unit (PDU) 19 AC outlet(s) 2U Black

CyberPower PDU24001 power distribution unit (PDU) 10 AC outlet(s) 1U Black

CyberPower PDU44007 power distribution unit (PDU) 19 AC outlet(s) 2U Black

CyberPower PDU44002 power distribution unit (PDU) 10 AC outlet(s) 1U Black

CyberPower PDU44003 power distribution unit (PDU) 16 AC outlet(s) 2U Black