CyberPower PDU42011 power distribution unit (PDU) 4 AC outlet(s) 0U Black
- AC outlets quantity: 4 AC outlet(s)
- Compliance certificates: RoHS
- Certification: UL62368 FCC Class A
- Nominal input voltage: 100 - 120 VAC
- AC input frequency: 50 Hz - 60
- Maximum current: 15 A
All 35 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Product Overview
The CyberPower PDU42011, a 4-outlet, compact switched power distribution unit (PDU), provides 120V 15A output. It distributes power to 4 x NEMA 5-15R receptacles from a single NEMA 5-15 plug with unfiltered electrical pass-through. The switched outlet receptacles can be managed individually or collectively over the network, using the CyberPower Management Console, a web browser, and the RJ45 Ethernet port for network connection, or locally by using the LCD controls.
Outlets can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads.
Switch-Free Design
Safeguards against accidental power shutdown.
Switchable Outlets
Provides local and remote control for individual and multiple outlets. Local control: turn on/turn off outlets and disable unused outlets. Remote control: restart outlets and devices, turn on/turn off, schedule power on/off sequencing, and disable unused outlets.
CyberPower Management Console
Built into Switched PDUs, a CyberPower Management Console is a hardware interface. Users can remotely switch individual PDU outlets or circuits on and off, either immediately or on a schedule, in order to power cycle connected equipment. It monitors the incoming power and power draw from the PDU, sends notifications based on the power status, and logs events.
Remote and Local Monitoring
The user is able to track PDU vitals both offsite and onsite. It also provides control to turn on/off individual outlets or circuits.
Automatic Event Notifications
Provide immediate updates about power events via email, SMS text, or SNMP traps.
Digital Display
Provides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.
Network-Grade Plugs and Outlets
Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.
Long Input Power Cord
Reaches distant power sources, allowing the PDU to be placed where it's needed.
Configurable Mounting Brackets
Allow for installation of the PDU in the following configurations: 0U Racmount (vertical), under counter, and over counter.
Durable Metal Housing
Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL62368 FCC Class A
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 100 - 120 VAC
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz - 60
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 15 A
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 100 - 120 VAC
- Output voltageThe electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48).
- 120 V
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 15 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Show all 35 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA 5-15P
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5-15R
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
- USB ports quantityThe total number of available Universal Serial Bus (USB) connection interfaces on the device.
- 2
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 220 mm
- DepthThe distance from the front to the back of something.
- 132 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 44 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 5.58 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL62368 FCC Class A
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 100 - 120 VAC
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz - 60
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 15 A
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 15 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 100 - 120 VAC
Features
- Output voltageThe electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48).
- 120 V
- Cable lengthHow long the cable is.
- 3 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 0U
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Current, Power, Voltage
Network
- Supported network protocolsNetwork protocols tested as compatible with this product e.g. FTP,HTML, POP.
- HTTP(S), SNMP v1/v3, Telnet, SSH, SMTP, IPv4, IPv6, NTP, SSL, TCP/IP, UDP
Design
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- TX / RX, Link
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal/Vertical
- Housing materialWhat the casing of the product is made of.
- Steel, Metal
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Display
- DisplayThe description of display that can includes display type, resolution, size etc.
- LCD
Performance
- On/off switchThe button which is pressed to switch the device on or off.
- No
Packaging data
- Package weightWeight of the packaged product.
- 7.62 kg
- Package widthThe distance from one side of the packaging to the other.
- 272.3 mm
- Package depthThe distance from the front to the back of the packaging.
- 214.9 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 130.1 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton Pulsar PDU. 10/16A, DIN sockets, rack power distribution unit (PDU)

CyberPower PDU81001G power distribution unit (PDU) 8 AC outlet(s) 1U Black

Eaton STS16. Pulsar Source Transfer Switch 16A power distribution unit (PDU)

CyberPower PDU42014 power distribution unit (PDU) 4 AC outlet(s) 0U Black

Eaton Comet PDU. 10/16A, IEC sockets, rack power distribution unit (PDU)