CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black
- AC outlets quantity: 16 AC outlet(s)
- Operating temperature (T-T): 0 - 60 °C
- Storage temperature (T-T): -15 - 65 °C
- Operating relative humidity (H-H): 0 - 95%
- Operating altitude: 0 - 3500 m
- Non-operating altitude: 0 - 14999 m
All 36 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The CyberPower PDU41021, a 1U rackmount, switched power distribution unit (PDU) provides 100-120Vac, 15A output via sixteen (16) NEMA 5-15R receptacles from a single NEMA 5-15P input power plug. The switched outlet receptacles can be managed individually or collectively over the network, using the CyberPower Management Console, a web browser, and the RJ45 Ethernet port for network connection, or locally from the Power Control Display.
Outlets can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads. The PDU41021 comes with a three-year limited warranty that covers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
- ManualUser manual ↗
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 16 AC outlet(s)
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 60 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3500 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 14999 m
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- UL, Federal Communications Commission (FCC), RoHS
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 120 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50-60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 15 A
Show all 36 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 16 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA 5-15P
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5-15R
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 215 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 44 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 3.81 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 60 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3500 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 14999 m
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- UL, Federal Communications Commission (FCC), RoHS
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 120 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50-60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 15 A
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 100-120 V
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Current, Power, Energy, Temperature, Humidity, Voltage, Alarm
- Management platformThe software or cloud-based system used to configure, monitor, and control the device (e.g., Cloudpath or EPICenter Network Management Software).
- SNMP
Network
- Supported network protocolsNetwork protocols tested as compatible with this product e.g. FTP,HTML, POP.
- IPv4/v6, SNMPv1/v3, HTTP/HTTPs, TCP/IP, UDP, DHCP, NTP, DNS, SMTP, SSH, SSL, TLS, Telnet, FTP, and Syslog, RADIUS, LDAP, LDAPS, Windows AD
Performance
- Daisy chainIndicates whether the product supports connecting multiple units in a series to a single output source.
- Yes
- Reset buttonIndicates whether the device features a dedicated button to restore the unit to its original factory settings.
- Yes
- On/off switchThe button which is pressed to switch the device on or off.
- Yes
Features
- Cable lengthHow long the cable is.
- 3.7 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 1U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal
- Housing materialWhat the casing of the product is made of.
- Metal
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Display
- DisplayThe description of display that can includes display type, resolution, size etc.
- LCD
Packaging data
- Package weightWeight of the packaged product.
- 5.53 kg
- Package widthThe distance from one side of the packaging to the other.
- 552.5 mm
- Package depthThe distance from the front to the back of the packaging.
- 406.4 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 127 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower PDU41001G power distribution unit (PDU) 8 AC outlet(s) 1U Black

CyberPower PDU41023 power distribution unit (PDU) 16 AC outlet(s) 1U Black

CyberPower PDU44001G power distribution unit (PDU) 10 AC outlet(s) 1U Black

CyberPower PDU11310 power distribution unit (PDU) 6 AC outlet(s) 1U Black

CyberPower PDU44005G power distribution unit (PDU) 10 AC outlet(s) 1U Black