CyberPower OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 525 W 6 AC outlet(s)
- Form factor: Mini Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 0.75 kVA
- Output power: 525 W
- Compliance certificates: RoHS
All 46 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
A mini-tower UPS with line interactive topology, the CyberPower PFC Sinewave OR750PFCLCD provides power protection (using sine wave output) and surge protection for department servers, workgroup servers, network devices, telecom appliances, and high-end audio/video equipment requiring PFC power source compatibility. The OR750PFCLCD uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently.
With a $150,000 connected equipment guarantee and a three-year warranty, you can trust CyberPower’s commitment to the quality of the OR750PFCLCD.
Battery Backup
Supplies power long enough for equipment to properly shut down when utility power fails. Helps prevent loss of data and minimizes the component stress caused by a hard shutdown.
Surge Protection
Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.
Line Interactive Topology
Exists when a line interactive UPS has an autotransformer that regulates low voltages (e.g., brownouts) and over voltages (e.g., spikes) without having to switch to battery.
Automatic Voltage Regulation (AVR)
Provides clean, consistent AC power by automatically increasing (boosting) low voltage without using battery power when incoming utility power experiences minor fluctuations.
Sine Wave Output
Provides power protection to ENERGY STAR 6.0 systems with Active PFC power supplies.
GreenPower UPS Bypass Design
Is a patented design that allows utility power to bypass the UPS transformer, when AC power is stable, which reduces energy consumption, noise, and heat buildup.
EMI/RFI Filters
Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
Multifunction LCD Panel
Displays immediate, detailed information on the UPS battery and power conditions, alerting users to potential problems before they can affect critical equipment and cause downtime.
Audible Alarms
Identify when the unit is running on battery power, overloaded, or has a low battery.
Resettable Circuit Breaker
Interrupts an electric current in a circuit when the current becomes too high.
Ultra Quiet Design
Minimizes noise during operation for a quieter work environment.
Industrial-Grade Metal Housing
Prolongs unit life with rugged casing made of impact-resistant material for maximum durability.
PowerPanel Business Edition Software
Provides IT professionals with tools for monitoring and managing the UPS and backup power. This software offers remote management functionality.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
- DocumentFunction Setup Guide ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Mini Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.75 kVA
- Output powerThe power that the device can produce.
- 525 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Input power cable
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- UL1778 4th cUL 107.3 FCC DOC Class B
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
Show all 46 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Mini Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.75 kVA
- Output powerThe power that the device can produce.
- 525 W
- Cable lengthHow long the cable is.
- 1.8 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 78 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 142 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 47/63 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 120 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 120 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- 5%
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 1030 J
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.7
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Low battery alarm, Overload alarm
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 162.5 mm
- DepthThe distance from the front to the back of something.
- 350.5 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 137 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 10.2 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
Packaging content
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Input power cable
Safety regulation & standards
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- UL1778 4th cUL 107.3 FCC DOC Class B
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 7 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Number of battery cellsThe total quantity of individual battery cells used to power the device, including configurations with primary and backup cells (e.g., 1+2).
- 2
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 5.5 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 15 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- RB1270X2D
Ports & interfaces
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA 5-15P
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 6 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OL6KRTMBTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
6000 W 13 AC outlet(s)

CyberPower HSTP3T10KEBC uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
9000 W

CyberPower UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA
360 W 3 AC outlet(s)

CyberPower PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
9000 W 13 AC outlet(s)

CyberPower UT850EG uninterruptible power supply (UPS) Line-Interactive 0.85 kVA
425 W 4 AC outlet(s)

CyberPower UT1000G uninterruptible power supply (UPS) Line-Interactive 1 kVA
500 W 8 AC outlet(s)