CyberPower OLS6KERT5U uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA 6000 W 9 AC outlet(s)
- Form factor: Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 6 kVA
- Output power: 6000 W
- Compliance certificates: CE, RoHS
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
CyberPower OLS6KERT5U is a high-efficiency UPS featuring online double-conversion topology, which provides seamless Pure Sine Wave power for mission-critical devices such as NAS, servers, DVRs/surveillance systems, transportation, infrastructure, and emergency systems. It’s typically integrated into the back office, server room, and data center environment.
With high output power factor, the UPS in a smaller footprint can provide more usable power and save rack space. The product allows multiple UPS units to be connected in parallel, achieving higher capacity and power redundancy. The pre-installed Maintenance Bypass PDU (MBP) offers quick and safe maintenance without power interruption. Moreover, the UPS is equipped with Remote Cloud Card to support remote monitoring via a web portal and the mobile app. The tiltable color LCD comes with an intuitive and graphical interface, allowing users to monitor and configure settings with ease. Besides, the battery charging current is adjustable via LCD setting to shorten charging time. It is also designed with relay-type dry contact port to support specific UPS event notifications for easy management.
Documents
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 6 kVA
- Output powerThe power that the device can produce.
- 6000 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- USB cable
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Sustainability complianceIndicates whether the product complies with established environmental and sustainability standards.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
Show all 62 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Metal
- Built-in fanIndicates whether the product has an integrated fan for active cooling.
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 6 kVA
- Output powerThe power that the device can produce.
- 6000 W
- Rack capacityThe spase that device fill in rack.
- 5U
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 110 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 300 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 200 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 1335 J
- Efficiency (ECO mode)The energy efficiency of the device when operating in its power-saving ECO mode, measured in %.
- 98%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 1
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 2%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 1.5%
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Carrying handle(s)Indicates whether the product is equipped with one or more integrated handles for easier transport.
- No
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Battery replacement, Fault, Overload alarm
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 661 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 213.5 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 75 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
Packaging content
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- USB cable
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Sustainability
- Sustainability complianceIndicates whether the product complies with established environmental and sustainability standards.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1500 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 1500 m
- Heat dissipationThe heat generated by the power supply.
- 1777 BTU/h
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 5.6 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 17.7 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 4 h
- Charging currentThe amount of electrical current supplied during the charging process, measured in amperes (e.g., 2/6/12).
- 4 A
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler, Terminal
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C13 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 9 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Management features
- ECO modeIndicates whether the device features an energy-saving mode to reduce power consumption during operation.
- Yes
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 62 dB
Power
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 575 mm
- Package depthThe distance from the front to the back of the packaging.
- 890 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 489 mm
- Package weightWeight of the packaged product.
- 94 kg
- Package typeThe type of product package e.g. box.
- Box
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OLS10KERT5U uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W 9 AC outlet(s)

CyberPower OLS8KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA
8000 W 8 AC outlet(s)

CyberPower PR3000RT2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA
3000 W 9 AC outlet(s)

CyberPower OLS5KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA
5000 W 8 AC outlet(s)

CyberPower PR1000RTXL2UC uninterruptible power supply (UPS) Line-Interactive 1 kVA
1000 W 8 AC outlet(s)

CyberPower PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA
675 W 6 AC outlet(s)