CyberPower OLS2000E uninterruptible power supply (UPS) 2.2 kVA 1600 W 4 AC outlet(s)
- Form factor: Mini Tower
- Product colour: Black
- Output power capacity: 2.2 kVA
- Output power: 1600 W
- Bundled software: PowerPanel BE
- Operating temperature (T-T): 0 - 40 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The Online S Series UPS is ideal for servers, networking equipment, workstations and other mission-critical applications which require Pure Sine Ware power protection. Featuring Online Double Conversion design and Zero Transfer Time, it can provide consistent and seamless Pure Sine Wave power to critical loads. With the add-on advantage of Extended Runtime (XL) battery packs, the UPS backup time can be extended to maximize workflow flexibility. An optional SNMP/HTTP Remote Management Capability enables remote management and control of the system through standard web browser. The included PowerPanel Business Edition management software provides corporate servers and critical workstations comprehensive network power management including unattended-shutdown, event logging, reporting, and notifications.
Features & Benefits
- Pure Sinewave Output
- Online (Double Conversion) UPS Topology
- Tower Form Factor
- EMI, RFI, Surge and Lightning Spike Protection
- Phone/Fax/Modem/DSL/Network Protection
- Auto-Restart/Auto-Charge
- Emergency Power Off (EPO) Port
- Multifunction LCD Readout
- USB & Serial Connectivity Port
- Smart Fan Speed Control By Load Level
- Economy Mode setting
- Smart Battery Management(SBM)
- Generator Mode setting
- SNMP/HTTP Remote Management Capability (Optional)
- PowerPanel Business Edition Software
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Mini Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Output power capacityThe maximum power that the device can produce.
- 2.2 kVA
- Output powerThe power that the device can produce.
- 1600 W
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- PowerPanel BE
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- Built-in fanIndicates whether the product has an integrated fan for active cooling.
- Yes
- Display typeType of display (screen) e.g. LCD.
- LCD
Show all 46 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Mini Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- Built-in fanIndicates whether the product has an integrated fan for active cooling.
- Yes
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Battery replacement
Features
- Output power capacityThe maximum power that the device can produce.
- 2.2 kVA
- Output powerThe power that the device can produce.
- 1600 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 120 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 280 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 208 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 95%
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Surge protection featuresSpecifies the types of communication and power lines protected against voltage spikes (e.g., Coax, Network, or Telephone).
- Fax, Modem, Network, Telephone
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Battery replacement
- Auto-restartIndicates whether the device automatically reboots itself after a power failure or a system crash.
- Yes
Software
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- PowerPanel BE
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 196 mm
- DepthThe distance from the front to the back of something.
- 416 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 337 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 23.8 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 7 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 6 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 16 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 5 h
- Automatic battery testIndicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.
- Yes
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 3
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Short circuit
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C14 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
- Modem (RJ-11) portsThe number of available RJ-11 connectors used for connecting telephone lines to the device.
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 1
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OLS3000E uninterruptible power supply (UPS) 3 kVA
2400 W 5 AC outlet(s)

CyberPower OLS1000E uninterruptible power supply (UPS) 1 kVA
800 W 4 AC outlet(s)

CyberPower EX650E-UK uninterruptible power supply (UPS) 0.65 kVA
360 W 3 AC outlet(s)

CyberPower OL8000E uninterruptible power supply (UPS) 8 kVA
7200 W 10 AC outlet(s)

CyberPower EC350G uninterruptible power supply (UPS) Standby (Offline) 0.35 kVA
255 W 8 AC outlet(s)

CyberPower OL6000E uninterruptible power supply (UPS) 6 kVA
5400 W 11 AC outlet(s)