CyberPower OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA 8000 W 6 AC outlet(s)
- Form factor: Rackmount
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 8 kVA
- Output power: 8000 W
- Compliance certificates: UL, cUL, CSA, Federal Communications Commission (FCC), RoHS
All 66 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The CyberPower Smart App Online OL6KRTHDL high-density design offers more power and longer run times. The OL6KRTHDL features double-conversion topology for seamless power protection and a pre-installed RMCARD205.
For monitoring, this UPS offers a new state-of-the-art, multi-function, color matrix LCD screen that is simple to set up and easy to use. The color-coded alerts provide clear status of the UPS and the screen orientation rotates automatically when placed into a tower configuration.
The OL6KRTHDL ensures maximum efficiency and capacity output with a Power Factor rating (PF) of 1. The energy-saving GreenPower UPS ECO Mode enables up to 96% efficiency while reducing power consumption and thermal dissipation. The variable 7-speed fan provides automatic thermal management, based on power load, to reduce noise.
The optional BP144VL2U01 Extended Battery Module (EBM) expands runtime and up to ten EBMs can be connected in a daisy-chain to the UPS for more backup power. Plus, it’s all backed by a three-year warranty (including batteries) and a $300,000 Connected Equipment Guarantee.
Documents
- BrochureProduct Brochure ↗
- DocumentQuick Start Guide ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 8 kVA
- Output powerThe power that the device can produce.
- 8000 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- UL, cUL, CSA, Federal Communications Commission (FCC), RoHS
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- USB cable
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Show all 66 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Control typeThe way in which the device is controlled.
- Buttons
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Power
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 8 kVA
- Output powerThe power that the device can produce.
- 8000 W
- Rack capacityThe spase that device fill in rack.
- 4U
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 200 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 240 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 196 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 245 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Output frequency regulationThe range or precision within which the output frequency can be adjusted or maintained, measured in Hz.
- 1 Hz
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- 2%
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 2430 J
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 1
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 1
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 98%
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 720 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 173 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 71.2 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- UL, cUL, CSA, Federal Communications Commission (FCC), RoHS
Packaging content
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- USB cable
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15239 m
- Heat dissipationThe heat generated by the power supply.
- 1589 BTU/h
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery replacement accessibilityIndicates whether a battery is removable and replaceable by the end-user, by an independent professional only, or non-removable.
- Non-removable
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 3.8 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 11 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 4 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Automatic battery testIndicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.
- Yes
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- BP192VL2U01
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 16
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 60 A
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- NEMA L6-20R, NEMA L6-30R
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA L6-30P
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 6 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type-B
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 66 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 890 mm
- Package depthThe distance from the front to the back of the packaging.
- 590 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 452.1 mm
- Package weightWeight of the packaged product.
- 90.7 kg
- Package typeThe type of product package e.g. box.
- Box
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OL10KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W 6 AC outlet(s)

CyberPower UT1500EG uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
900 W 4 AC outlet(s)

CyberPower UT2200EG uninterruptible power supply (UPS) Line-Interactive 2.2 kVA
1320 W 4 AC outlet(s)

CyberPower UT2200EG uninterruptible power supply (UPS) Line-Interactive 2.2 kVA
1320 W 4 AC outlet(s)

CyberPower OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2700 W 6 AC outlet(s)

CyberPower OLS1000A uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA
900 W 4 AC outlet(s)