CyberPower OL6000RT3UTAA uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA 5400 W 4 AC outlet(s)
- Form factor: Rackmount/Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 6 kVA
- Output power: 5400 W
- Compliance certificates: RoHS
All 58 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The CyberPower Smart App Online OL6000RT3UTAA UPS has been manufactured to comply with the Federal Trade Agreement Act (TAA). This network-grade UPS protects mission-critical servers, routers and telecom equipment with true sine wave output and double-conversion topology for seamless power protection. The OL6000RT3UTAA also offers generator compatibility and delivers clean AC power with zero transfer time.
Other features include a flexible rack/tower design for easy installation, extendable LCD control panel, Smart Battery Management, Fast Charge Technology, and energy-saving GreenPower UPS ECO Mode. The CyberPower OL6000RT3UTAA UPS is protected by a three-year warranty as well as a $300,000 Connected Equipment Guarantee.
Data Line Protection
Prevents power surges that travel through telephone and Ethernet lines from causing damage to electronics.
Double-Conversion Topology
Provides consistent, clean, and nearly perfect power, regardless of the condition of incoming power. Systems with this technology operate on isolated DC power 100% of the time and have a zero transfer time because they never need to switch to battery. Double-conversion UPS systems are designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave Output
Provides power protection to ENERGY STAR 6.0 systems with Active PFC power supplies.
Extendable LCD Panel
Displays UPS statuses and customizable operating settings from up to 10 ft. away (with optional cable). The extendable LCD control panel can be configured in English, Spanish, or French for ease of use.
Extended Battery Module (EBM)
Extends runtime by adding EBMs. This UPS allows for up to ten added modules.
Fast Charge Technology
Allows UPS batteries to return to 100% capacity more rapidly by utilizing a built-in charger inside each EBM. Restores a complete charge within 5 hours regardless of the number of EBMs.
Smart Battery Management (SBM)
Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
GreenPower UPS ECO Mode
Improves UPS efficiency up to 96%; saves on electrical and cooling costs.
Hot-Swappable Batteries
Eliminate downtime related to UPS power maintenance for continuous power availability.
Critical & Non-Critical Loads
The UPS has two banks of outlets which can be configured so that the non-critical loads shut off after a set timeframe to provide additional runtime for the critical load outlet. Users can prioritize their equipment runtimes to maximize the output of the UPS to meet their power requirements.
Emergency Power Off (EPO)
Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
Backfeed Protection
Prevents the risk of electric shock from any electric current feeding back from the UPS through the input terminals when utility power is lost. Backfeed protection isolates the UPS and allows service personnel to safely work on the utility power.
Generator Compatible
Provides stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
Converter Mode
Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.
USB & Serial Connectivity
Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.
EMI/RFI Filters
Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
Audible Alarms
Identify when the model is running on battery power, overloaded, or has a low battery.
Resettable Circuit Breaker
Interrupts an electric current in a circuit when the current becomes too high.
LED Status Lights
Indicate Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.
Rack/Tower Versatility
Allows for horizontal rack or vertical tower installation.
PowerPanel Business Edition Software
Provides IT professionals with tools for monitoring and managing the UPS and backup power. This software offers remote management functionality. Free software download available. See the Resources tab.
Cisco Compatible
This CyberPower UPS system is a Cisco EnergyWise compliant end device.
ENERGY STAR
This model is an ENERGY STAR certified Uninterruptible Power Supply (UPS) system. ENERGY STAR is the trusted, government-backed symbol for energy-efficient products and practices that help save money and protect the environment.
Three-Year Warranty
CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date. See warranty for details.
Connected Equipment Guarantee
CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 6 kVA
- Output powerThe power that the device can produce.
- 5400 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- UL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
- Sustainability certificatesThe environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).
- ENERGY STAR
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
Show all 58 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Steel
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Power, Power fail, Battery replacement
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 6 kVA
- Output powerThe power that the device can produce.
- 5400 W
- Rack capacityThe spase that device fill in rack.
- 6U
- Cable lengthHow long the cable is.
- 3 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 120 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 280 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40 - 70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 200 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 2670 J
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacement
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 660 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 264 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 100 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
Safety regulation & standards
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- UL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
Sustainability
- Sustainability certificatesThe environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).
- ENERGY STAR
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 7 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 5 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 15 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 4 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- RB1270X10
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 20
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- NEMA L6-20R, NEMA L6-30R
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA L6-30P
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.99
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 600 mm
- Package depthThe distance from the front to the back of the packaging.
- 900 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 638 mm
- Package weightWeight of the packaged product.
- 124.8 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower RT650EI uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA
400 W 4 AC outlet(s)

CyberPower PR5000ELCDRTXL5U uninterruptible power supply (UPS) Line-Interactive 5 kVA
4000 W 11 AC outlet(s)

CyberPower PR5000LCDRTXL5UTF uninterruptible power supply (UPS) Line-Interactive 5 kVA
4000 W 5 AC outlet(s)

CyberPower CP1350EPFCLCD uninterruptible power supply (UPS) Line-Interactive 1.35 kVA
810 W 6 AC outlet(s)

CyberPower UT650EI uninterruptible power supply (UPS) Line-Interactive 0.65 kVA
360 W 4 AC outlet(s)

CyberPower CP850EPFCLCD uninterruptible power supply (UPS) Line-Interactive 0.85 kVA
540 W 6 AC outlet(s)