CyberPower LCD OL3T030KERTHDS uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA 30000 W
- Form factor: Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 30 kVA
- Output power: 30000 W
- Output connections: L1, L2, L3, N, G
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
CyberPower OL3T030KERTHDS guarantees backup power and protection for IT equipment such as FTTx devices, networking devices and NAS/storage devices. It is typically integrated in the back office, server room, and data center environments.
With integrated IGBT technology and intelligent DSP-based control, the product produces less input total harmonic distortion (THDi), achieving higher power efficiency. Supporting flexible placement, the selected product can be installed in a rack or tower configuration, and it's compatible with 19” standard rack cabinets. In addition, the product features parallel expansion, allowing the connections of multiple UPS units to reach higher capacity. Its color LCD with touch panel enables easy monitoring and configuration of the system. Furthermore, the LCD panel can also be adjusted to vertical or horizontal display through LCD setting.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 30 kVA
- Output powerThe power that the device can produce.
- 30000 W
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- L1, L2, L3, N, G
- Overload protectionIndicates whether the device includes a safety mechanism to prevent damage caused by electrical or mechanical overstress.
- Yes
- BypassSpecifies the method used to route power around the main circuitry to ensure continuous operation during maintenance or failure (e.g. Manual or Automatic).
- Automatic
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE, BSMI, IEC62040-1, IEC62040-2, CNS 14757-2, CNS 14843-1
Show all 69 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Metal
- Control typeThe way in which the device is controlled.
- Touch
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 30 kVA
- Output powerThe power that the device can produce.
- 30000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 132 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 478 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- 1%
- Transfer time (Line Mode to Battery Mode)The time required for the device to switch from mains power to battery power during a power failure, measured in ms.
- 0 ms
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 95.8%
- Efficiency (ECO mode)The energy efficiency of the device when operating in its power-saving ECO mode, measured in %.
- 98.9%
- Efficiency (Battery mode)The ratio of output power to input power when the device is operating using battery power, expressed as a percentage.
- 95.5%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.9
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Total Harmonic Distortion (THD) (linear load)The percentage of harmonic distortion present in the output waveform when powered by a linear load, measured in %.
- 1%
- Total Harmonic Distortion (THD) (non-linear load)The percentage of harmonic distortion present in the output waveform when the device is powering a non-linear load, measured in %.
- 3%
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Battery replacement, Fault, Low battery alarm, Overload alarm
- Socket circuit breakerIndicates whether the unit includes a dedicated circuit breaker for protecting socket outlets.
- Yes
Other features
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- L1, L2, L3, N, G
- Overload protectionIndicates whether the device includes a safety mechanism to prevent damage caused by electrical or mechanical overstress.
- Yes
- BypassSpecifies the method used to route power around the main circuitry to ensure continuous operation during maintenance or failure (e.g. Manual or Automatic).
- Automatic
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 219 mm
- DepthThe distance from the front to the back of something.
- 760 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 483 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 44.7 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE, BSMI, IEC62040-1, IEC62040-2, CNS 14757-2, CNS 14843-1
Packaging content
- Batteries includedIndicates whether the required batteries are supplied with the product.
- Yes
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -40 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Charging currentThe amount of electrical current supplied during the charging process, measured in amperes (e.g., 2/6/12).
- 3.6 A
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
- Rechargeable batteryIndicates whether the battery is rechargeable.
- Yes
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 40
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 48.5 A
- Power Factor Correction (PFC) typeSpecifies the method used by the power supply unit to improve the efficiency of power delivery and reduce harmonic distortion, such as Active or Passive PFC.
- Active
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Terminal
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- Terminal
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-485
- Parallel ports quantityThe number of parallel ports. Parallel ports, also known as printer ports, are a type of interface found on computers (personal and otherwise) for connecting peripherals. In computing, a parallel port is a parallel communication physical interface. Parallel ports were common in the 1980s and '90s (mostly conforming to industry standard IEEE 1284) but are now being replaced by USBs and other ports.
- 4
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 1
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 66 dB
Management features
- ECO modeIndicates whether the device features an energy-saving mode to reduce power consumption during operation.
- Yes
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower LCD OL3T040KERTHDS uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA
40000 W

CyberPower LCD HSTP3T40KE uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA
36000 W

CyberPower GX150C2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
1000 W 13 AC outlet(s)

CyberPower LCD HSTP3T30KE uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA
27000 W

CyberPower Online S Series OL2K2RM uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA
2400 W 7 AC outlet(s)

CyberPower OL750RTHD uninterruptible power supply (UPS) Double-conversion (Online) 0.75 kVA
750 W 8 AC outlet(s)