CyberPower OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA 9000 W 19 AC outlet(s)
- Form factor: Rackmount
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 10 kVA
- Output power: 9000 W
- Battery type: RB1290X20
All 44 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Smart App UPS | Network, Servers and Datacenter
The CyberPower Smart App Online OL10000RT3UTF rack/tower uninterruptible power supply (UPS) with step-down transformer, LCD control panel, and pure sine wave output safeguards mission-critical servers, data center and telecom equipment, VoIP, and internetworking hardware that require seamless power correction. Its Double-Conversion Topology is generator compatible and delivers consistent and clean standard 120V or 200-240V AC power with zero transfer time to protect connected equipment and prevent costly business interruptions. Auto-bypass insures connected equipment continues to operate seamlessly when an overload or internal fault is detected.
Configurable GreenPower UPS ECO Mode improves UPS efficiency to 95% and reduces electrical and cooling costs. Smart Battery Management uses a 3 cycle charging mode to improve battery life while reducing heat being generated.
The LCD control panel provides 38 different settings to check status and customize the operating settings for the OL10000RT3UTF, plus it can be removed and mounted separately from the UPS for ease of use regardless of where the UPS is installed. Functions include menus for checking power status on different parameters, settings for setup, control, and testing of the UPS, and selections for event logging. With a DB26 cable the LCD control panel can be removed from the UPS and relocated up to 10ft. away from the UPS for ease of viewing when installed in hard to reach locations.
The UPS incorporates microprocessor-based fully digital control and includes PowerPanel Business Edition providing the user unsurpassed flexibility and control. An optional SNMP/HTTP Remote Management adapter supports remote management and control of the OL10000RT3UTF through a standard web browser.
The OL10000RT3U unit has a capacity of 10,000VA / 9,000Watts (0.9 power factor) that can be configured for an output of 200V, 208V, 220V, 230V and 240V +/- 2%. It features two NEMA L6-20R, four NEMA L6-30R, twelve NEMA 5-20R receptacles, hardwire terminal block for output, hardwire input connection, and maintenance-free, hot swappable, user-replaceable batteries. This unit offers connectivity via one HID USB, one DB9 serial and one emergency power off port. Network grade surge suppression and EMI/RFI filters increase the immunity of the load to noise disturbances. The runtimes are expandable by adding a hot swappable, user replaceable BP240V30ART3U Extended Battery Module.
A Three-Year Warranty ensures that this UPS has passed our highest quality standards in design, assembly, material or workmanship and further protection is offered by a $300000 Connected Equipment Guarantee.
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 9000 W
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- RB1290X20
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL, CSA, FCC DOC
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
Show all 44 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 9000 W
- Rack capacityThe spase that device fill in rack.
- 9U
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 120 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 280 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 200 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 95%
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 5%
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
Power
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- RB1290X20
- Number of batteries supportedThe number of batteries that can be used with the product.
- 20
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 660 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 400 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 174.6 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL, CSA, FCC DOC
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 4 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 11 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 5 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5–20R, NEMA L6-20R, NEMA L6-30R
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 19 AC outlet(s)
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
- Modem (RJ-11) portsThe number of available RJ-11 connectors used for connecting telephone lines to the device.
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 1
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OL8000RT3UTF uninterruptible power supply (UPS) 8 kVA
7200 W 19 AC outlet(s)

CyberPower CP750LCDTAA uninterruptible power supply (UPS) 0.75 kVA
420 W 8 AC outlet(s)

CyberPower PR1000LCDRT2UTAA uninterruptible power supply (UPS) 1 kVA
700 W 8 AC outlet(s)

CyberPower CP550SLGTAA uninterruptible power supply (UPS) 0.55 kVA
330 W 8 AC outlet(s)

CyberPower PR1000LCDTAA uninterruptible power supply (UPS) 1 kVA
700 W 8 AC outlet(s)

CyberPower CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA
900 W 10 AC outlet(s)