CyberPower OL10000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA 9000 W 13 AC outlet(s)
- Form factor: Rackmount/Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 10 kVA
- Output power: 9000 W
- Compliance certificates: RoHS
All 58 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The CyberPower Smart App Online OL10000RT3UPDUTF is an 8U rack/tower UPS with double-conversion topology, Maintenance Bypass Switch, and Step-Down Transformer. It provides sine wave output to mission-critical applications and equipment requiring seamless power protection. Generator-compatible, the OL10000RT3UPDUTF delivers consistent and clean 120V or 200-240V AC power with zero transfer time. Auto-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected. The Maintenance Bypass Switch allows for the UPS power module to be hot-swapped for service or replacement without cutting power to the connected equipment.
The OL10000RT3UPDUTF features an extendable LCD control panel (with optional cable), Smart Battery Management charging design, Fast Charge Technology, and the energy-saving GreenPower UPS ECO Mode. This model can use the BP240V30ART3U Extended Battery Module for expanded runtime and faster restoration of full backup power. The OL10000RT3UPDUTF comes with a three-year warranty (including batteries) and a $300,000 Connected Equipment Guarantee.
Data Line Protection
Prevents power surges that travel through telephone and Ethernet lines from causing damage to electronics.
Double-Conversion Topology
Provides consistent, clean, and nearly perfect sine wave power, regardless of the condition of incoming power. Systems with this technology operate on isolated DC power 100% of the time and have a zero transfer time because they never need to switch to battery. Double-Conversion UPS systems are designed for high-end, mission-critical system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave Output
Provides power protection to ENERGY STAR 6.0 systems with Active PFC power supplies.
Step-Down Transformer
Supports 120V and 200-240V output requirements with a single UPS solution. With six (6) NEMA 5-20R outlets available, users will have sufficient outlets to connect multiple 120V devices running at 15A and/or 20A. (A CyberPower PDU can be purchased if additional outlets are required.)
Maintenance Bypass Switch
Provides IT managers the ability to service or replace the UPS without powering down the connected equipment. A patented interlock bracket enables the UPS to automatically switch to internal bypass mode, making the hot-swap process easier and quicker to complete.
Extendable LCD Panel
Displays UPS statuses and customizable operating settings. The 43-setting LCD control panel can be removed and mounted up to ten feet away from the UPS (with optional cable). Users can check UPS status, manage setup and control, and run battery test options. Status and log menus provide UPS vitals, including input and output voltage levels, battery information, runtime estimates, load information, event and fault logging, and other system information. The Configuration menu offers IT managers the ability to customize the UPS operation.
Multiple Language Options
The LCD Control Panel can be configured in English, Spanish, French, and German for ease of use.
Extended Battery Module (EBM)
Extends runtime by adding EBMs. An online Series UPS allows for up to ten added modules.
Fast Charge Technology
Allows UPS batteries to return to 100% capacity more rapidly by utilizing a built-in charger inside each EBM. Restores a complete charge within 5 hours regardless of the number of EBMs.
Smart Battery Management (SBM)
Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process. The first cycle charges the battery to full capacity, the second cycle enters float mode, and the final cycle turns the charger off and allows the battery to naturally discharge (rest) until it reaches a set point. After a slight discharge, the UPS will restart the process, ensuring that runtimes are maintained.
GreenPower UPS ECO Mode
Improves UPS efficiency up to 95%; saves on electrical and cooling costs.
Hot-Swappable Batteries
Eliminate downtime related to UPS power maintenance for continuous power availability.
Critical & Non-Critical Loads
The UPS has two banks of outlets which can be configured so that the non-critical loads shut off after a set timeframe to provide additional runtime for the critical load outlet. Users can prioritize their equipment runtimes to maximize the output of the UPS to meet their power requirements.
Emergency Power Off (EPO)
Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
Backfeed Protection
Prevents the risk of electric shock from any electric current feeding back from the UPS through the input terminals when utility power is lost. Backfeed protection isolates the UPS and allows service personnel to safely work on the utility power.
Generator Compatible
Provides stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
Converter Mode
Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.
USB & Serial Connectivity
Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.
EMI/RFI Filters
Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
Audible Alarms
Identify when the unit is running on battery power, overloaded, or has a low battery.
Resettable Circuit Breaker
Interrupts an electric current in a circuit when the current becomes too high.
LED Status Lights
Indicate Power On, On-Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.
Rack/Tower Versatility
Allows for horizontal rack or vertical tower installation.
Documents
- ManualUser manual ↗
- ManualUser manual ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 9000 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Serial, USB cable
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- UL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
- Sustainability certificatesThe environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).
- ENERGY STAR
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
Show all 58 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Steel
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Power, Battery replacement
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 9000 W
- Rack capacityThe spase that device fill in rack.
- 8U
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 120 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 280 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40 - 70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 120 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 2670 J
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 5%
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Surge protection featuresSpecifies the types of communication and power lines protected against voltage spikes (e.g., Coax, Network, or Telephone).
- Network, Telephone
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Low battery alarm, Overload alarm, Battery replacement
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 820 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 352 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 160.8 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
Packaging content
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Serial, USB cable
Safety regulation & standards
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- UL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
Sustainability
- Sustainability certificatesThe environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).
- ENERGY STAR
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 4 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 11 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 5 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- RB1290X20
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 20
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload, Short circuit
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Terminal, NEMA 5–20R, NEMA L6-20R, NEMA L6-30R
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 13 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- Modem (RJ-11) portsThe number of available RJ-11 connectors used for connecting telephone lines to the device.
- 2
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.9
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 620 mm
- Package depthThe distance from the front to the back of the packaging.
- 1120 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 1028 mm
- Package weightWeight of the packaged product.
- 207.5 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OL10KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
9000 W 1 AC outlet(s)

CyberPower OL10000RT3UPDU uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
9000 W 7 AC outlet(s)

CyberPower Intelligent LCD uninterruptible power supply (UPS) Line-Interactive 1.35 kVA
810 W 6 AC outlet(s)

CyberPower OL8KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA
7200 W 1 AC outlet(s)

CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA
700 W 8 AC outlet(s)

CyberPower OL8000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA
7200 W 13 AC outlet(s)