CyberPower OL10000RT3U uninterruptible power supply (UPS) 10 kVA 9000 W 4 AC outlet(s)
- Form factor: Rackmount/Tower
- Product colour: Black
- Output power capacity: 10 kVA
- Output power: 9000 W
- Battery type: 12V/9AH
- Output connections: 3 xNEMA L6-30R & 1 x Hardware Terminal Block
All 53 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Smart App UPS | Network, Servers & Datacenter
The CyberPower Smart App Online OL10000RT3U rack/tower uninterruptible power supply (UPS) with LCD control panel and pure sine wave output safeguards mission-critical servers, data center and telecom equipment, VoIP, and internetworking hardware that require seamless power correction. Its Double-Conversion Topology is generator compatible and delivers consistent and clean AC power with zero transfer time, protecting connected equipment and preventing costly business interruptions. Auto-bypass insures connected equipment continues to operate seamlessly when an overload or internal fault is detected.
Configurable GreenPower UPS ECO Mode improves UPS efficiency to 95% and reduces electrical and cooling costs. Smart Battery Management (SBM) uses a 3 cycle charging mode to improve battery life and while reducing heat being generated.
The LCD control panel provides 38 different settings to check status and customize the operating parameters for the OL10000RT3U, plus it can be removed and mounted separately from the UPS for ease of use regardless of where the UPS is installed. Functions include menus for checking power status on (16) different parameters, (19) settings for setup, control, and testing of the UPS, and (3) selections for event logging. With a DB26 cable (sold separately) the LCD control panel can be removed from the UPS and relocated up to 10ft. away from the UPS for ease of viewing when installed in hard to reach locations.
The UPS incorporates microprocessor-based fully digital control and includes PowerPanel Business Edition providing the user unsurpassed flexibility and control. An optional SNMP/HTTP Remote Management adapter (RMCARD302) supports remote management and control of the OL10000RT3U through a standard web browser.
The OL10000RT3U unit has a capacity of 10,000VA / 9,000Watts (0.9 power factor) that can be configured for an output of 200V, 208V, 220V, 230V and 240V +/- 2%. It features three (3) NEMA L6-30R receptacles, hardwire terminal block for output, hardwire input connection, and maintenance-free, hot swappable, user-replaceable batteries. This unit offers connectivity via one (1) HID USB, one (1) DB9 serial and one (1) emergency power off (EPO) port. Network grade surge suppression and EMI/RFI filters increase the immunity of the load to noise disturbances. The runtimes are expandable by adding a hot swappable, user replaceable BP240V50ART3U Extended Battery Module (EBM).
A Three-Year Warranty ensures that this UPS has passed our highest quality standards in design, assembly, material or workmanship and further protection is offered by a $300,000 Connected Equipment Guarantee.
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 9000 W
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- 12V/9AH
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- 3 xNEMA L6-30R & 1 x Hardware Terminal Block
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- Hardwire
- Management platformThe software or cloud-based system used to configure, monitor, and control the device (e.g., Cloudpath or EPICenter Network Management Software).
- SNMP/HTTP
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- PowerPanel
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
Show all 53 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Steel
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 9000 W
- Rack capacityThe spase that device fill in rack.
- 6U
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 200 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 240 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 200 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 95%
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 5%
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Surge protection featuresSpecifies the types of communication and power lines protected against voltage spikes (e.g., Coax, Network, or Telephone).
- Network, Telephone
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Battery replacement
Power
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- 12V/9AH
Other features
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- 3 xNEMA L6-30R & 1 x Hardware Terminal Block
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- Hardwire
Management features
- Management platformThe software or cloud-based system used to configure, monitor, and control the device (e.g., Cloudpath or EPICenter Network Management Software).
- SNMP/HTTP
Software
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- PowerPanel
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 660 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 266.7 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 103 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- ETL
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Number of battery cellsThe total quantity of individual battery cells used to power the device, including configurations with primary and backup cells (e.g., 1+2).
- 20
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 4 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 11 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 5 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.9
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Packaging data
- Package dimensions (WxDxH)The external width, depth, and height of the product's packaging, measured in mm.
- 600 x 900 x 638 mm
- Package weightWeight of the packaged product.
- 126.8 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OL6000RT3U uninterruptible power supply (UPS) 6 kVA
5400 W 4 AC outlet(s)

CyberPower PR1000LCD uninterruptible power supply (UPS) 1 kVA
700 W 8 AC outlet(s)

CyberPower PR1500LCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
1050 W 8 AC outlet(s)

CyberPower OL8000RT3U uninterruptible power supply (UPS) 8 kVA
7200 W 4 AC outlet(s)

CyberPower CPS1000E uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA
700 W 2 AC outlet(s)

CyberPower CP750LCD uninterruptible power supply (UPS) Standby (Offline) 0.75 kVA
420 W 8 AC outlet(s)