CyberPower MBP63A2 power distribution unit (PDU) 3 AC outlet(s) 2U
- AC outlets quantity: 3 AC outlet(s)
- Operating temperature (T-T): 0 - 40 °C
- Operating relative humidity (H-H): 0 - 90%
- Nominal input voltage: 220 - 240 V
- Maximum current: 63 A
- Cable length: 1 m
All 15 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Designed for datacenters and other electrically demanding applications, the CyberPower MBP63A2 Maintenance Bypass Power Distribution Unit (MBP PDU), allows the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS. The MBP63A2 provides 208V nominal output to (1) NEMA L6-20R, (1) NEMA L6-30R and (1) Hardwire Terminal Block receptacle.
Depending on UPS model, either a 3.3-foot AC cord or hardwire terminal block connects to the output power of the UPS. The UPS draws input power from the MBP63A2 separate from the outlets or terminal block for connected devices. When the switch on the front of the MBP63A2 is turned from Normal to Bypass, or from Bypass to Normal, the power that the MBP supplies to connected devices moves from one input power source to another. The LED display indicates which power source is active.
Rugged, industrial-grade metal housing protects the MBP63A2. With a 2U form factor, this PDU can be mounted horizontally or vertically in a standard server rack, on a wall or in a tower configuration. The MBP63A2 is UL and RoHS compliant. A three-year limited warranty covers the PDU.
Power Distribution
Delivers AC power to servers, equipment, and connected devices via a power distribution unit.
Maintenance Bypass
Qualified personnel can use the bypass feature to disconnect the PDU from the UPS without disrupting power to connected equipment. This feature allows connected equipment to operate seamlessly during maintenance periods, battery replacement, or UPS installation.
Manual Bypass Switch
When the Manual Bypass Switch is turned to Normal, connected equipment is supplied by UPS output. When the Manual Bypass Switch is turned to Bypass, connected equipment is supplied by utility power.
MBP Detection Cable
Communicates directly between the UPS and Maintenance Bypass PDU to safely coordinate the bypass switch operation. When the PDU bypass switch operation is initiated by removing the cover, the MBP Detection Cable sends a signal to the UPS to internally transfer to bypass mode to prevent UPS damage.
Network-Grade Plugs and Outlets
Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.
2U Form Factor & Mounting Hardware
The 2U form factor is made to be mounted horizontally or vertically in a standard server rack, on a wall or in a tower configuration.
Durable Metal Housing
Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 3 AC outlet(s)
- AC outlet typesThe type of outlet for AC electricity.
- NEMA L6-20R, NEMA L6-30R
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 433 mm
- DepthThe distance from the front to the back of something.
- 125 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 86.5 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 4 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 220 - 240 V
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 63 A
Features
- Cable lengthHow long the cable is.
- 1 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 2U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Switched
- Housing materialWhat the casing of the product is made of.
- Metal
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower PDU33105 power distribution unit (PDU) 44 AC outlet(s) 0U Black

CyberPower MBP63AHVHW82U power distribution unit (PDU) 8 AC outlet(s) 2U Black, Silver

CyberPower PDU33108 power distribution unit (PDU) 42 AC outlet(s) 0U Black

CyberPower PDU31102 power distribution unit (PDU) 24 AC outlet(s) 0U Black

CyberPower PDU33110 power distribution unit (PDU) 18 AC outlet(s) 0U Black