CyberPower CP1600EPFCLCD uninterruptible power supply (UPS) Line-Interactive 1.6 kVA 1000 W 6 AC outlet(s)
- Form factor: Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 1.6 kVA
- Output power: 1000 W
- Nominal output voltage: 230 V
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
CyberPower CP1600EPFCLCD with Pure Sine Wave output safeguards mid- to high-end computer systems, servers and networking hardware that use conventional and Active Power Factor Correction (PFC) power supplies. Designed with GreenPower UPS Technology to improve UPS operating efficiency and to minimize its energy consumption, this UPS delivers significant energy cost savings over conventional UPS systems.
The UPS provides Automatic Voltage Regulation (AVR) to maintain stable voltage for connected equipment. The product features data line protection with high-speed transmission to safeguard communication equipment against surges/spikes as well as supply 1Gbps speed to transmit data. With tiltable color LCD panel , users can monitor key power and battery information at a glance. The PowerPanel Power Management Software allows user to perform real-time monitoring and configuration.
Videos & documents
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1.6 kVA
- Output powerThe power that the device can produce.
- 1000 W
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 220-240 V
- Overload protectionIndicates whether the device includes a safety mechanism to prevent damage caused by electrical or mechanical overstress.
- Yes
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
- Batteries includedIndicates whether the required batteries are supplied with the product.
- Yes
Show all 67 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Control typeThe way in which the device is controlled.
- Buttons
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1.6 kVA
- Output powerThe power that the device can produce.
- 1000 W
- Country of originCountry where the device is made. Aka Country of manufacture (COM).
- China
- Cable lengthHow long the cable is.
- 1.83 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 169 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 271 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 230 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 230 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 405 J
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Fault, Low battery alarm, Overload alarm
- Detachable power cordIndicates whether the power cable can be removed from the soundbar for easier transport or replacement.
- Yes
- Socket circuit breakerIndicates whether the unit includes a dedicated circuit breaker for protecting socket outlets.
- Yes
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
- Overload protectionIndicates whether the device includes a safety mechanism to prevent damage caused by electrical or mechanical overstress.
- Yes
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 220-240 V
- Number of batteries supportedThe number of batteries that can be used with the product.
- 1
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 10 A
- Power Factor Correction (PFC) typeSpecifies the method used by the power supply unit to improve the efficiency of power delivery and reduce harmonic distortion, such as Active or Passive PFC.
- Active
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
- Power source typeWhat the power source is.
- AC
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 100 mm
- DepthThe distance from the front to the back of something.
- 355 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 280 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 11 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RoHS
Packaging content
- Batteries includedIndicates whether the required batteries are supplied with the product.
- Yes
- Quick installation guideIndicates whether a simplified, fast-start manual is included with the product.
- Yes
Sustainability
- Sustainability complianceIndicates whether the product complies with established environmental and sustainability standards.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
- Heat dissipationThe heat generated by the power supply.
- 24 BTU/h
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 8 ms
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 2.6 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 9.7 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- RBP0142
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Type F
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C14 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 6 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 2
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type A/USB Type-C
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
Logistics data
- Harmonized System (HS) codeThe standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.
- 8504408590
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 195 mm
- Package depthThe distance from the front to the back of the packaging.
- 466 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 370 mm
- Package weightWeight of the packaged product.
- 13 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OL5KRTHDL uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA
5000 W 4 AC outlet(s)

CyberPower CP1200EIPFCLCD uninterruptible power supply (UPS) Line-Interactive 1.2 kVA
720 W 6 AC outlet(s)

CyberPower OL6KRTHDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
6000 W 4 AC outlet(s)

CyberPower PRL3000RT2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA
3000 W 9 AC outlet(s)

CyberPower PDU24302 uninterruptible power supply (UPS)

CyberPower PRL1500RT2UC uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
1500 W 8 AC outlet(s)