CyberPower LCD CP1500AVRLCD3 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA 900 W 12 AC outlet(s)
- Form factor: Mini Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 1.5 kVA
- Output power: 900 W
- Certification: RoHS UL1778 cUL 107 5th FCC DOC Class B
All 45 specificationsProduct page at cyberpowersystems.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
A mini-tower UPS with line interactive topology, the CyberPower Intelligent LCD CP1500AVRLCD3 provides battery backup (using simulated sine wave output) and surge protection for desktop computers, workstations, networking devices, and home entertainment systems. The CP1500AVRLCD3 uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently. The CP1500AVRLCD3 comes with a three-year warranty (including coverage of batteries) and a $500,000 Connected Equipment Guarantee.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Mini Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1.5 kVA
- Output powerThe power that the device can produce.
- 900 W
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- RoHS UL1778 cUL 107 5th FCC DOC Class B
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Show all 45 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Mini Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Plastic
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Power, Fault
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1.5 kVA
- Output powerThe power that the device can produce.
- 900 W
- Cable lengthHow long the cable is.
- 1.8 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Simulated sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 120 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 120 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 57/63 Hz
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 1500 J
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.6
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Overload alarm, Low battery alarm, Alarm when on battery, Fault
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 100 mm
- DepthThe distance from the front to the back of something.
- 350 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 259 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 10.8 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- RoHS UL1778 cUL 107 5th FCC DOC Class B
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15239 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Lead-Acid
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Number of battery cellsThe total quantity of individual battery cells used to power the device, including configurations with primary and backup cells (e.g., 1+2).
- 2
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 3 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 12 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- RB1290X2E
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5-15R
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA 5-15P
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 12 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type A/USB Type-C
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower LCD Intelligent uninterruptible power supply (UPS) Line-Interactive 1.35 kVA
815 W 12 AC outlet(s)

CyberPower CP1500PFCRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
1000 W 8 AC outlet(s)

CyberPower OLS2000EA uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA
1800 W 4 AC outlet(s)

CyberPower OL5KSTF uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA
5000 W 12 AC outlet(s)

CyberPower LCD BRG1500AVRLCD2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
900 W 12 AC outlet(s)

CyberPower LCD HSTP3T10K uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W