
CyberPower CP1350EPFCLCD-UK uninterruptible power supply (UPS) Line-Interactive 1.35 kVA 810 W 6 AC outlet(s)
- Form factor: Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 1.35 kVA
- Output power: 810 W
- Compliance certificates: RoHS, CE
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
CyberPower CP1350EPFCLCD-UK with Pure Sine Wave output safeguards mid- to high-end computer systems, servers and networking hardware that use conventional and Active Power Factor Correction (PFC) power supplies. Designed with GreenPower UPS Technology to improve UPS operating efficiency and to minimize its energy consumption, this UPS delivers significant energy cost savings over conventional UPS systems.
The UPS provides Automatic Voltage Regulation (AVR) to maintain stable voltage for connected equipment. The product features data line protection with high-speed transmission to safeguard communication equipment against surges/spikes as well as supply 1Gbps speed to transmit data. With tiltable color LCD panel , users can monitor key power and battery information at a glance. The PowerPanel Power Management Software allows user to perform real-time monitoring and configuration.
Documents
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1.35 kVA
- Output powerThe power that the device can produce.
- 810 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS, CE
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Show all 40 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1.35 kVA
- Output powerThe power that the device can produce.
- 810 W
- Cable lengthHow long the cable is.
- 1.83 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 169 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 271 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 405 J
- Surge protection featuresSpecifies the types of communication and power lines protected against voltage spikes (e.g., Coax, Network, or Telephone).
- Network
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Low battery alarm, Overload alarm, Fault
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 100 mm
- DepthThe distance from the front to the back of something.
- 355 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 280 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 10 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS, CE
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Heat dissipationThe heat generated by the power supply.
- 19 BTU/h
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 8 ms
Battery
- Battery replacement accessibilityIndicates whether a battery is removable and replaceable by the end-user, by an independent professional only, or non-removable.
- End-user
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 2.1 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 9.6 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C14 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 6 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type A/USB Type-C
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
Power
- Power Factor Correction (PFC) typeSpecifies the method used by the power supply unit to improve the efficiency of power delivery and reduce harmonic distortion, such as Active or Passive PFC.
- Active
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OLS10KERT5U-NEMA uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W 4 AC outlet(s)

CyberPower CP2000EIPFCRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA
1200 W 8 AC outlet(s)

CyberPower OLS5KEA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA
4800 W 11 AC outlet(s)

CyberPower CP1600EIPFCRM2U uninterruptible power supply (UPS) Line-Interactive 1.6 kVA
1000 W 8 AC outlet(s)

CyberPower CP900EIPFCLCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA
540 W 6 AC outlet(s)

CyberPower CP1200EIPFCRM2U uninterruptible power supply (UPS) Line-Interactive 1.2 kVA
720 W 8 AC outlet(s)