
CyberPower BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA 390 W 3 AC outlet(s)
- Form factor: Compact
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 0.65 kVA
- Output power: 390 W
- Compliance certificates: CE, RCM, RoHS
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
CyberPower BU650E provides home and office users with a reliable battery backup and safeguards office PCs and other electronic devices from surges, spikes, brownouts and other power irregularities. As all CyberPower UPSs are designed with fireproof plastic housing, this product provides an outstanding fire-resistant capability (as compared to similar products) to minimize possible damage to valuable assets in case of fire.
The innovative Battery Management Technology significantly increases battery efficiency and promotes increased battery performance and longer battery life. Configurable alarm allows users to switch the audible alarm on or off during battery mode to avoid unnecessary disturbances. Its desktop design allows users to place it easily on desks or other tight spaces.
Documents
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Compact
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.65 kVA
- Output powerThe power that the device can produce.
- 390 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RCM, RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE , RCM
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 50 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Show all 46 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Compact
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Plastic
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.65 kVA
- Output powerThe power that the device can produce.
- 390 W
- Cable lengthHow long the cable is.
- 1.2 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Simulated sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 167 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 295 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 150 J
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Low battery alarm, Fault, Overload alarm, Alarm when on battery
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 158 mm
- DepthThe distance from the front to the back of something.
- 240 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 91.5 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 4.1 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, RCM, RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE , RCM
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 50 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 90%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 3000 m
- Heat dissipationThe heat generated by the power supply.
- 36.8 BTU/h
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Type I
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 3 AC outlet(s)
- Number of outlets (Protection)The total number of power sockets provided on the device that are protected against electrical surges and spikes.
- 3
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 2.83 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload, Surge protection
Display
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 4 ms
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 40 dB
Logistics data
- Harmonized System (HS) codeThe standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.
- 85078000
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 118 mm
- Package depthThe distance from the front to the back of the packaging.
- 281 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 225 mm
- Package weightWeight of the packaged product.
- 4.23 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower Online S Series Online Double Conversion USV 1000VA/900WTower, ECO Mode, LCD, USB, Smart-Slot

CyberPower Online S Series OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2700 W 10 AC outlet(s)

CyberPower Online S Series Online Double Conversion USV 3000VA/2700WTower, ECO Mode, LCD, USB, Smart-Slot

CyberPower Online S Series OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2700 W 10 AC outlet(s)

CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA
2000 W 10 AC outlet(s)

CyberPower Online S Series PR1500RTXL2UCTAA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
2400 W 8 AC outlet(s)