Ariston DUAL 55 XD0B-O Air conditioner outdoor unit White
- Type: Air conditioner outdoor unit
- Multi-split
- Product colour: White
- Air conditioner functions: Cooling, Dehumidifying, Heating, Ventilating
- Inverter technology
- Outdoor unit noise level: 65 dB
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
Specifications
Key specifications
- TypeCharacteristics of the device.
- Air conditioner outdoor unit
- Multi-splitIndicates whether the system can be connected to multiple units.
- Yes
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Dehumidifying, Heating, Ventilating
- Inverter technologyAn “inverter” is a power conversion circuit that electronically regulates the voltage, current and frequency of products such as air conditioners.
- Yes
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 65 dB
- Cooling airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the cooling cycle, measured in cubic meters per hour (m³/h).
- 2100 m³/h
- Heating airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the heating cycle, typically measured in cubic meters per hour.
- 2100 m³/h
- Outdoor units quantityThe total number of external components included in the system.
- 1
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 80 cm
Show all 47 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Air conditioner outdoor unit
- Multi-splitIndicates whether the system can be connected to multiple units.
- Yes
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Dehumidifying, Heating, Ventilating
- Seasonal efficiency rating (cooling) (SEER)The Seasonal Energy Efficiency Ratio (SEER) is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is often measured as a ratio of British thermal units (BTU) to watt-hours.
- 5.6
- Seasonal efficiency rating (heating) (SCOP) (Warmer heating season)The seasonal coefficient of performance for heating in a warmer climate, representing the energy efficiency ratio over an entire heating season.
- 4.15
- Seasonal efficiency rating (heating) (SCOP) (Average heating season)The ratio of the total heat energy delivered by the device to the total electrical energy consumed during an entire heating season, based on average climate conditions.
- 3.8
- Cooling energy efficiency (EER, W/W)The ratio of the cooling capacity to the electrical power input, measured in watts per watt (W/W).
- 2.89
- Heating energy efficiency (COP, W/W)The ratio of heat energy delivered to the electrical energy consumed by the unit, expressed as watts per watt.
- 3.33
- Cooling capacity in watts (nominal)The amount of heat the unit can remove from a space under nominal operating conditions, measured in watts.
- 5034 W
- Cooling capacity in watts (min)The minimum amount of heat energy the unit can remove from a space, measured in watts.
- 1183 W
- Cooling capacity in watts (max)The maximum amount of heat energy the unit can remove from a space or component, measured in watts.
- 5395 W
- Heating capacity in watts (nominal) (Average heating season)The average amount of thermal energy the unit can provide for heating during a typical heating season, measured in watts.
- 4427 W
- Heating capacity in watts (min)The minimum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 1250 W
- Heating capacity in watts (max)The maximum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 5708 W
- Cooling capacity (min)The minimum amount of heat the unit can remove from an indoor space, typically measured in BTU/h or kilowatts.
- 4039 BTU/h
- Cooling capacity (max)Maximum cooling capacity of the air conditioner.
- 18419 BTU/h
- Heating capacity (min)The minimum amount of heat the unit can produce to warm a space, measured in BTU/h.
- 4268 BTU/h
- Heating capacity (max)The maximum amount of heat the unit can generate to warm a space, measured in BTU/h.
- 19487 BTU/h
- Refrigerating medium weightThe total mass of the coolant gas used in the cooling system, measured in grams or kilograms.
- 1.9 kg
- Compressor typeThe technology used by the pump to compress the refrigerant and circulate it through the system (e.g. Inverter, Linear, or Rotary).
- Rotary
- Operating temperature (cooling) (T-T)The range of ambient temperatures within which the device can operate effectively, measured in °C.
- -15 - 50 °C
- Operating temperature (heating) (T-T)The range of ambient temperatures, measured in degrees Celsius, within which the unit can effectively operate while in heating mode (e.g. -25°C to +18°C).
- -15 - 30 °C
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Inverter technologyAn “inverter” is a power conversion circuit that electronically regulates the voltage, current and frequency of products such as air conditioners.
- Yes
- Refrigerating mediumThe type of refrigerant gas used to transfer heat (e.g., R600a or R290).
- R410A
Outdoor unit
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 65 dB
- Cooling airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the cooling cycle, measured in cubic meters per hour (m³/h).
- 2100 m³/h
- Heating airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the heating cycle, typically measured in cubic meters per hour.
- 2100 m³/h
- Outdoor units quantityThe total number of external components included in the system.
- 1
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 80 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 33.3 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 55.4 cm
- Outdoor unit weightThe total mass of the external component, measured in g.
- 37.8 kg
Power
- Energy efficiency class (heating) (Average heating season)The energy efficiency rating of the unit during the heating season, indicated by a scale of letter and plus symbols (e.g. A+++).
- A
- Energy efficiency class (heating) (Warmer heating season)The energy efficiency rating of the air conditioning unit during the heating season in warmer climates, indicated by a scale such as A+++, A++, or A+.
- A+
- Energy efficiency class (cooling) (legacy scale)This is a measure of the energy efficiency of the air conditioning (AC) when it is used to cool air. There are energy efficiency classes from A+++ to G, A+++ being the most energy efficient, G the least efficient.
- A+
- Annual energy consumption (cooling)This is a measure of the energy used in a year by the air conditioning (AC) when it is used to cool air.
- 315 kWh
- Annual energy consumption (heating) (Warmer heating season)The total amount of electricity used for heating purposes over a year based on a milder climate profile, measured in kilowatt-hours.
- 1536 kWh
- Annual energy consumption (heating) (Average heating season)The estimated amount of electrical energy used for heating during a standard heating season, measured in kilowatt-hours.
- 1631 kWh
- Power consumption (cooling) (min)The minimum amount of electrical power required to operate the unit in cooling mode, measured in Watts.
- 106 W
- Power consumption (cooling) (max)The maximum amount of electrical energy used by the unit during the cooling process, measured in watts.
- 2228 W
- Power consumption (heating) (min)The minimum amount of electrical power required by the unit to operate in heating mode, measured in Watts.
- 248 W
- Power consumption (heating) (max)The maximum amount of electrical power required by the unit during the heating process, measured in watts (W) or kilowatts (kW).
- 1941 W
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- CurrentThe amount of electrical current flowing through the device, measured in amperes (A).
- 20 A
Performance
- Remotely operatedThe device can be controlled by remote control, which is a device that controls an apparatus by means of radio or infrared signals.
- Yes
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Ariston PRIOS 25 UD0-I Air conditioner indoor unit White
Specs & where to buy

Ariston 3381060 air conditioner Air conditioner outdoor unit White
Specs & where to buy

Ariston PRIOS 35 UD0-I Air conditioner indoor unit White
Specs & where to buy

Ariston Aeres 30 UD0-I Air conditioner indoor unit White
Specs & where to buy

Ariston PRIOS 35 MD0-O Air conditioner outdoor unit White
Specs & where to buy

Hotpoint VENUS 35 UC8-I air conditioner Air conditioner indoor unit White
Specs & where to buy