
APC SY16KI uninterruptible power supply (UPS) 16 kVA 11200 W
- Product colour: Beige
- Output power capacity: 16 kVA
- Output power: 11200 W
- Output connections: (8)IEC 320 C13 (1)Hard Wire 3-wire (H N + G)
- Input connection type: Hard Wire 3 wire (1PH+N+G)
- Dimensions (WxDxH): 609.6 x 689.9 x 1199.9 mm
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Features
Audible Alarms, Automatic Self Test, Battery modules connected in parallel, Built-in automatic bypass, Built-in manual bypass, Built-in SmartSlot, Built-in Web/SNMP management, Double Conversion On-Line, EPO, Hot Swap Batteries, Hot Swap Electronics, Input Power Factor Correction, Intelligent Battery Management, LCD AlphaNumeric Display, N+1 Redundancy, Overload Indicator, Replace Batt Indicator, Scalable Run Time, Sine-wave output, User Replaceable batteries, Wide input voltage range
Includes
CD with software, User Manual
Specifications
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Beige
Features
- Output power capacityThe maximum power that the device can produce.
- 16 kVA
- Output powerThe power that the device can produce.
- 11200 W
- InterfaceInterface ports to connect pieces of equipment. USB (Universal Serial Bus) has become the most popular wired interface to connect peripherals. USB 2.0 supports speeds up to 480 Mbit/s (USB 1: 12 Mbit/s). The interface FireWire is also known as the IEEE 1394 standard. Enhanced IDE (EIDE)is sometimes referred to as Fast ATA, Fast IDE or ATA-2.
- DB-9 RS-232, RJ-45 10 Base-T ethernet for web/ SNMP/ Telnet management
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
Power
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 230 V
Other features
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- (8)IEC 320 C13 (1)Hard Wire 3-wire (H N + G)
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- Hard Wire 3 wire (1PH+N+G)
- Dimensions (WxDxH)Dimensions of the product (Width x Depth x Height).
- 609.6 x 689.9 x 1199.9 mm
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
- Output voltage noteAdditional technical details or specific conditions regarding the delivered output voltage of the unit.
- Configurable for 220: 230 or 240 nominal output voltage
Software
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- - PowerChute Network Shutdown - PowerChute plus for AIX v4.2.3 - PowerChute plus for HP-UX v 4.2.3 - PowerChute plus for Linux v 4.5.2 - PowerChute plus for Novell NetWare v4.3.3 - PowerChute plus for Red Hat Linux v 4.5.2.1 - PowerChute plus for Solaris v 4.5 - PowerChute Plus for Windows NT/2000 (English) v. 5.2.1
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Battery
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 5.2 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 17.1 min
- Replacement battery cartridgeSpecifies the compatible replacement battery cartridge required to restore the power backup capacity of the unit.
- APC Replacement Battery SYBATT
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC AP9608 uninterruptible power supply (UPS)

APC AP9618 uninterruptible power supply (UPS)

APC 5-Port 10Base-T Hub SmartSlot Card uninterruptible power supply (UPS)

APC SYMMETRA EXTEND. RUN FRAME uninterruptible power supply (UPS)

APC Symmetra XR Frame w/2 SYBATT Scalable to 4, 220-/240V uninterruptible power supply (UPS)

APC Symmetra XR Frame w/12 SYBATT 220-240V uninterruptible power supply (UPS)
Accessories & compatible products

APC Symmetra 4-16kVA Power Module (4kVA)

APC Power Cord, C13 to C14, 2.5m

APC SmartSlot Expansion Chassis

APC Rack PDU power distribution unit (PDU) Black

APC Rack Automatic Transfer Switch, 12A, 230V power distribution unit (PDU) Beige

APC MASTERSWITCH PWR RECEPT 2U 12A 230V
(4)C13 power distribution unit (PDU) Beige