APC SUA500PDR-S uninterruptible power supply (UPS) 0.5 kVA 320 W 3 AC outlet(s)
- Product colour: Black
- Output power capacity: 0.5 kVA
- Output power: 320 W
- Compliance certificates: RoHS
- Operating temperature (T-T): 0 - 40 °C
- Storage temperature (T-T): -15 - 45 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Flexible Design
Available in a wide range of configurations to suit any operating environment
Multiple mounting methods
Allows for standardization on one product for use in different environments.
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Cold-start capable
Provides temporary battery power when the utility power is out.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Specifications
Key specifications
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Output power capacityThe maximum power that the device can produce.
- 0.5 kVA
- Output powerThe power that the device can produce.
- 320 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Show all 30 specificationsShow key specifications only
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Output power capacityThe maximum power that the device can produce.
- 0.5 kVA
- Output powerThe power that the device can produce.
- 320 W
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 75 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 154 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 47/63 Hz
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 540 J
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 94%
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 362 mm
- DepthThe distance from the front to the back of something.
- 171 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 148 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 12.9 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LED
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 7.4 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 21 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 2 h
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 1
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 3 AC outlet(s)
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 297 mm
- Package depthThe distance from the front to the back of the packaging.
- 481 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 297 mm
- Package weightWeight of the packaged product.
- 13.3 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Symmetra PX 96kW Scalable, 400V with Modular Power Distribution

APC Smart-UPS X uninterruptible power supply (UPS) Line-Interactive 3 kVA
2700 W 11 AC outlet(s)

APC BX1500G uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
865 W 10 AC outlet(s)

APC SMT750R2X122 uninterruptible power supply (UPS) Line-Interactive 0.75 kVA
500 W 6 AC outlet(s)

APC SMT1000J uninterruptible power supply (UPS) Line-Interactive 1 kVA
670 W 8 AC outlet(s)

APC Back-UPS Pro 500 uninterruptible power supply (UPS) 0.5 kVA
300 W 4 AC outlet(s)