APC STS630
- Operating temperature (T-T): 0 - 40 °C
- Storage temperature (T-T): -40 - 70 °C
- Operating relative humidity (H-H): 20 - 80%
- RS-232 ports: 1
- Product colour: Grey
- Display: LCD
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Dual Input Power Sources
Supplies redundant AC power to connected equipment. Two AC lines power the unit and if the primary AC power fails, the unit will automatically switch to the alternative power source.
Quick Transfer Rate
Transfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.
Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Smallest footprint
Minimizes your real estate expenses
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Serial connectivity
Provides management of the UPS via a serial port.
LED status indicators
Quickly understand unit and power status with visual indicators.
Specifications
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 715 mm
- DepthThe distance from the front to the back of something.
- 825 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1900 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 327 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -40 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 80%
Ports & interfaces
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Grey
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Power
Display
- DisplayThe description of display that can includes display type, resolution, size etc.
- LCD
Safety regulation & standards
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- IEC 60950
Other features
- Electromagnetic compatibilityList of countries and their respective regulatory agency standards with which the product complies.
- IEC /EN 61000-6-2
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC 60439-1, IEC 60439-3 for PDU, IEC / EN 61000-4-2, level 4, IEC / EN 61000-4-3, level 3, IEC / EN 61000-4-4, level 4, IEC / EN 61000-4-5, level 4
Power
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Over voltage, Overload
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Input currentThe amount of electrical current drawn by the device during operation, typically measured in amperes (A) or milliamperes (mA).
- 630 A
Features
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 380 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 415 V
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 247 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 498 V
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC UPSILON STS630 4POLE 415V 1900MM

APC Static Transfer Switch, Upsilon STS 630, 4 pole, 380-400V
1900mm

APC AP4424 Automatic Transfer Switch (ATS)

APC Static Transfer Switch, Upsilon STS 630, 4 pole, 380-400V, IP00

APC AP4423 Automatic Transfer Switch (ATS)

APC Static Transfer Switch, Upsilon STS 630, 3 pole, 380-415V
1900mm