
APC SMTL1000RM2UCNC uninterruptible power supply (UPS) Line-Interactive 1 kVA 800 W 6 AC outlet(s)
- Form factor: Rackmount
- Product colour: Stainless steel
- UPS topology: Line-Interactive
- Output power capacity: 1 kVA
- Output power: 800 W
- Rack mount kit
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Description
This APC Smart-UPS is designed for IT professionals or network administrators to maintain business uptime and continuity. The 1000VA line interactive 2U rackmount UPS provides pure sine wave power to support critical electronics during power disruptions. It comes with NEMA 5-15P input and 6 NEMA 5-15R outlets. This rackmount UPS is tower convertible with the mounting stabilizing feet (SMTL2USF sold separately). It has a preinstalled Network Management Card for UPS network-based monitoring and management. It comes with PowerChute Network Shutdown that provides graceful shutdown of physical servers, virtual machines, and HCI clusters. It offers cloud-based remote power monitoring, UPS firmware upgrades, remote diagnostics and proactive email notifications with recommended actions. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. It provides surge protection against lightning strikes, power sags, brownouts and surges. The SMTL UPS has a 5-year warranty on the UPS and Lithium-ion battery.
Documents
- ManualUser manual ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Stainless steel
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1 kVA
- Output powerThe power that the device can produce.
- 800 W
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- RJ-45, USB cable
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Show all 54 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Stainless steel
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 1 kVA
- Output powerThe power that the device can produce.
- 800 W
- Rack capacityThe spase that device fill in rack.
- 2U
- Cable lengthHow long the cable is.
- 2.4 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 120 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 120 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 120 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 120 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 680 J
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 5%
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- 41 dB
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Low battery alarm
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 438 mm
- DepthThe distance from the front to the back of something.
- 318 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 86 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 16.3 kg
Packaging content
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- RJ-45, USB cable
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 7620 m
- Heat dissipationThe heat generated by the power supply.
- 135 BTU/h
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 10 ms
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Lithium-Ion (Li-Ion)
- Battery life (max)Maximum battery life. Mobile Mark (2002) is the standard often used to benchmark battery life time.
- 10 year(s)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 3 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5-15R
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA 5-15P
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 6 AC outlet(s)
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 3
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type-A
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 1
- SmartSlotIndicates whether the unit features a dedicated expansion slot for installing optional network management or communication cards.
- Yes
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 47.2 mm
- Package depthThe distance from the front to the back of the packaging.
- 584 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 229 mm
- Package weightWeight of the packaged product.
- 18.6 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Back-UPS 500VA, 230V, AVR, IEC Sockets

APC BVX900L-LM uninterruptible power supply (UPS) Line-Interactive 0.9 kVA
480 W 6 AC outlet(s)

APC GVSUPS75KFS uninterruptible power supply (UPS) 75 kVA
75000 W

APC BVX700LU-LM uninterruptible power supply (UPS) Line-Interactive 0.7 kVA
360 W 4 AC outlet(s)

APC BVX700LUI-MS uninterruptible power supply (UPS) Line-Interactive 0.7 kVA
360 W 2 AC outlet(s)

APC SRTL5KRM2UT uninterruptible power supply (UPS) Double-conversion (Online) 4.9 kVA
4900 W 4 AC outlet(s)