APC SMT3000RMI2U + WBEXTWAR3YR-SP-04 uninterruptible power supply (UPS) Line-Interactive 3 kVA 2700 W 9 AC outlet(s)
- Form factor: Rackmount
- Product colour: Black, Grey
- UPS topology: Line-Interactive
- Output power capacity: 3 kVA
- Output power: 2700 W
- Number of phases: 1
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
APC Smart-UPS,2700 Watts /3000 VA,Input 230V /Output 230V, Interface Port USB, Rack Height 2 U
Includes: CD with software, Documentation CD, Rack mounting hardware, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Grey
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 3 kVA
- Output powerThe power that the device can produce.
- 2700 W
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Show all 50 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Grey
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 3 kVA
- Output powerThe power that the device can produce.
- 2700 W
- Rack capacityThe spase that device fill in rack.
- 2U
- Cable lengthHow long the cable is.
- 2 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 151 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 302 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 320 J
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 98.3%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Auto-restartIndicates whether the device automatically reboots itself after a power failure or a system crash.
- Yes
Power
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 480 mm
- DepthThe distance from the front to the back of something.
- 683 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 86 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 44.3 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- C-tick, CE, EN 60950, EN/IEC 62040-1-1, EN/IEC 62040-2, GOST, GS Mark, IRAM, VDE, WEEE
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 3.2 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 11.5 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 3 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Automatic battery testIndicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.
- Yes
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 9 AC outlet(s)
- Number of output IEC jumpersThe total quantity of IEC-standard jumper cables provided for connecting the unit to other devices.
- 3
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 600 mm
- Package depthThe distance from the front to the back of the packaging.
- 980 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 254 mm
- Package weightWeight of the packaged product.
- 51.7 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC SMT750RMI2U + WBEXTWAR3YR-SP-02 uninterruptible power supply (UPS) Line-Interactive 0.75 kVA
500 W 4 AC outlet(s)
Specs & where to buy

APC SMT1500RMI2U + WBEXTWAR3YR-SP-03 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
1000 W 4 AC outlet(s)
Specs & where to buy

APC SMX1500RMI2U + WBEXTWAR3YR-SP-03 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
1200 W 8 AC outlet(s)
Specs & where to buy

APC SMT1000RMI2U + WBEXTWAR3YR-SP-03 uninterruptible power supply (UPS) 1 kVA
700 W 4 AC outlet(s)
Specs & where to buy

APC SMX3000RMHV2UNC + WBEXTWAR3YR-SP-04 uninterruptible power supply (UPS) 3 kVA
2700 W 9 AC outlet(s)
Specs & where to buy

APC MGE Galaxy 300 uninterruptible power supply (UPS) 15 kVA
12000 W
Specs & where to buy