APC Smart-UPS SC 1500VA 120V uninterruptible power supply (UPS) 1.5 kVA 865 W
- Output power capacity: 1.5 kVA
- Output power: 865 W
- Output connections: (6) NEMA 5-15R
- Input connection type: NEMA 5-15P
- Dimensions (WxDxH): 432 x 463 x 89 mm
- Nominal output voltage: 120 V
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Multiple mounting methods
Allows for standardization on one product for use in different environments.
Front-access servicing
Simplifies installation and maintenance while minimizing space requirements.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Cold-start capable
Provides temporary battery power when the utility power is out.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Network manageable
Provides remote management of the UPS over the network.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial Connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers
Enables a quick recovery from overload events.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.
Specifications
Features
- Output power capacityThe maximum power that the device can produce.
- 1.5 kVA
- Output powerThe power that the device can produce.
- 865 W
- Cable lengthHow long the cable is.
- 1.83 m
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 445 J
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Other features
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- (6) NEMA 5-15R
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- NEMA 5-15P
- Dimensions (WxDxH)Dimensions of the product (Width x Depth x Height).
- 432 x 463 x 89 mm
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 120 V
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 120 V
Weight & dimensions
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 21.4 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CSA,FCC Part 15 Class A,UL Listed
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -5 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 7.6 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 20.9 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 45 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC AIS 3000 uninterruptible power supply (UPS) 10 kVA
8000 W

APC Smart-UPS XL 3000VA 230V Tower (5U) uninterruptible power supply (UPS) 3 kVA
2700 W

APC Smart-UPS 3000VA uninterruptible power supply (UPS) 3 kVA
2700 W

APC Smart-UPS XL 2200VA, 5U uninterruptible power supply (UPS) 2.2 kVA
1980 W

APC Smart-UPS XL 4ft Battery Pack Extension Cable SUA48 series packs uninterruptible power supply (UPS)

APC Symmetra LX 8kVA UPS uninterruptible power supply (UPS)
6400 W