APC Smart-UPS RT 3000VA 208V uninterruptible power supply (UPS) 3 kVA 2100 W
- Output power capacity: 3 kVA
- Output power: 2100 W
- Battery type: Lead-Acid
- Interface: Smart-Slot
- Output connections: 2x NEMA L6-20R 2x NEMA L6-30R
- Input connection type: NEMA L6-30P
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Scalable runtime
Allows additional run time to be quickly added as needed.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Specifications
Features
- Output power capacityThe maximum power that the device can produce.
- 3 kVA
- Output powerThe power that the device can produce.
- 2100 W
- InterfaceInterface ports to connect pieces of equipment. USB (Universal Serial Bus) has become the most popular wired interface to connect peripherals. USB 2.0 supports speeds up to 480 Mbit/s (USB 1: 12 Mbit/s). The interface FireWire is also known as the IEEE 1394 standard. Enhanced IDE (EIDE)is sometimes referred to as Fast ATA, Fast IDE or ATA-2.
- Smart-Slot
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Power
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- Lead-Acid
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
Other features
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- 2x NEMA L6-20R 2x NEMA L6-30R
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- NEMA L6-30P
- Dimensions (WxDxH)Dimensions of the product (Width x Depth x Height).
- 130 x 660 x 432 mm
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
- Output voltage noteAdditional technical details or specific conditions regarding the delivered output voltage of the unit.
- Configurable for 208 or 240 nominal output voltage
Weight & dimensions
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 54.5 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CSA,FCC Part 15 Class A,UL 1778
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Design
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Battery
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 14.1 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 33.9 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 2.50 h
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Smart-UPS RT 6kVA uninterruptible power supply (UPS)
4200 W

APC Smart-UPS RT 5kVA uninterruptible power supply (UPS)
3500 W

APC Smart-UPS RT 10000VA, 208V uninterruptible power supply (UPS) 10 kVA
8000 W

APC SYMMETRA 3 Battery uninterruptible power supply (UPS)

APC Smart-UPS Power Module uninterruptible power supply (UPS)