APC Smart-UPS RT 10000VA RM 230V uninterruptible power supply (UPS) 10 kVA 8000 W 8 AC outlet(s)
- Form factor: Rackmount
- Product colour: Black
- Output power capacity: 10 kVA
- Output power: 8000 W
- Battery type: RBC44
- Certification: C-tick, CE, EN 50091-1, EN 50091-3
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Scalable runtime
Allows additional run time to be quickly added as needed.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 8000 W
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- RBC44
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- C-tick, CE, EN 50091-1, EN 50091-3
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Show all 33 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 8000 W
- Rack capacityThe spase that device fill in rack.
- 6U
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 160 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 280 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 47/63 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 92%
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 3%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 7%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Power
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- RBC44
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 432 mm
- DepthThe distance from the front to the back of something.
- 736 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 263 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 110.9 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- C-tick, CE, EN 50091-1, EN 50091-3
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Battery
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 2.2 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 8 AC outlet(s)
- Number of output IEC jumpersThe total quantity of IEC-standard jumper cables provided for connecting the unit to other devices.
- 4
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 1
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC MXA103 uninterruptible power supply (UPS) 7.5 kVA 8 AC outlet(s)

APC MGE Galaxy 3500 uninterruptible power supply (UPS) 20 kVA
16000 W

APC Smart-UPS VT uninterruptible power supply (UPS) 30 kVA

APC Smart-UPS RT 5000VA RM 230V uninterruptible power supply (UPS) 5 kVA
350 W 10 AC outlet(s)

APC SURT18KRMXLJ uninterruptible power supply (UPS) 1.8 kVA 6 AC outlet(s)

APC Smart-UPS RT 8000VA RM 230V uninterruptible power supply (UPS) 8 kVA
6400 W 8 AC outlet(s)