APC PDPM72F-5U power distribution unit (PDU) Black
- Certification: UL
- Nominal input voltage: 208 V
- AC input frequency: 60 Hz
- Maximum current: 200 A
- Nominal output voltage: 208 V
- Load capacity: 72 VA
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
APC Modular Rack Distribution Panel, 72kW, 200A, 208V, 18 Pole, 5U
APC Modular Power Distribution , Input: 208V 3PH , Input Connections: Hard Wire 5-wire (3PH+N+G)
UL-listed Touch-safe backplane
Adding Power Distribution Modules requires no hot work; one trained user can safely add new modules without removing power to the existing PDU load
Network management capability
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet.
Built-in Web/SNMP management
Full-featured management via a Web browser as well as comprehensive management from a Network Management System.
Low Cost Power Distribution
Provides a number of outlets to bring power to rack equipment at an affordable price.
Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Information Displays
Indicates the status of the AC sources powering the units, as well as indicates which source is set as the primary source and which source is currently supplying power to the load. This provides a visual depiction of the power flow from the input to the load. This allows the user to quickly glance at the power flow and status of the input sources without connecting to the unit.
Current Monitoring
Monitors the aggregate current draw per power distribution unit.
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities.
Local and web-based monitoring
Status available to customers both in the data center and remotely
Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Multiple distribution options
Superior design flexibility enables a wide range of customer requirements to be addressed.
UL-listed Touch-safe backplane
Adding Power Distribution Modules requires no hot work; one trained user can safely add new modules without removing power to the existing PDU load
Multiple distribution options
Superior design flexibility enables a wide range of customer requirements to be addressed.
Toolless installation of breakers
Install factory-assembled Power Distribution Modules in under ten minutes - no tools are required
Safety
Enhance user safety with isolation at all touch points and with positive locking mechanisms that reduce the risk of accidental disconnection
Current Monitoring
Monitors the aggregate current draw per power distribution unit.
Network management capability
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet.
Ease of system expansion
Power Distribution Modules provide an option to expand power distribution capability as power demands increase.
System mobility
PDU equipment can easily be relocated to accommodate a changing data center environment.
Smallest footprint
Minimizes your real estate expenses
Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Specifications
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 483 mm
- DepthThe distance from the front to the back of something.
- 711 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 229 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 30.1 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 200 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 72 VA
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- 5-wire(3PH+N+G)
Management features
- Management platformThe software or cloud-based system used to configure, monitor, and control the device (e.g., Cloudpath or EPICenter Network Management Software).
- Web/SNMP
Design
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Monitored
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Rack capacityThe spase that device fill in rack.
- 5U
Packaging data
- Package weightWeight of the packaged product.
- 34 kg
- Package widthThe distance from one side of the packaging to the other.
- 610 mm
- Package depthThe distance from the front to the back of the packaging.
- 889 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 406 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC IT Power Distribution Module 3x1 Pole 3 Wire 20A 250V L5-20 UL
260cm 380cm 500cm power distribution unit (PDU) 3 AC outlet(s) Black

APC Symmetra PX 100kW Bottom Feed Side Car
300mm power distribution unit (PDU) Black

APC IT Power Distribution Module 3x1 Pole 3 Wire 20A 250V L5-20 UL
680cm 860cm 1040cm power distribution unit (PDU) 36 AC outlet(s) Black

APC PDPM100G6F-M power distribution unit (PDU) Black

APC PDM3450CS50-1040 power distribution unit (PDU) 1 AC outlet(s) Black