APC PD80G6FK1-M power distribution unit (PDU) Black
- Operating temperature (T-T): 0 - 40 °C
- Storage temperature (T-T): -15 - 45 °C
- Operating relative humidity (H-H): 0 - 95%
- Storage relative humidity (H-H): 0 - 95%
- Nominal input voltage: 480 V
- Nominal output voltage: 208 V
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
- Load test port provides simple connection for full testing of a Symmetra PX UPS.
- Breaker maintenance bypass panel to isolate the UPS from the critical load.
- Smallest footprint minimizes your real estate expenses.
- Circuit Breaker Panel provides breaker positions for distribution to racks and power zones.
- System mobility PDU equipment can easily be relocated to accommodate a changing data center environment.
- Wide Range of applications configure-to-order process allows APC to configure, install, and test complete system before shipping.
- Step down transformer placed upstream of the UPS to avoid inrush current and saturation eliminating need to oversize transformer.
- Local and web-based monitoring available to customers both in the data center and remotely.
- Front-access servicing simplifies installation and maintenance while minimizing space requirements.
Specifications
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 737 mm
- DepthThe distance from the front to the back of something.
- 914 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 2057 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 740 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 480 V
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 80 VA
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 135 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 277.5 A
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC PDRPPNX10-M power distribution unit (PDU) Black
Specs & where to buy

APC SBPAR30K40H-WP power distribution unit (PDU) Black
Specs & where to buy

APC Rack PDU, Basic, 1U, 30A, 208V
(10) C13
Specs & where to buy

APC SBPAR10K20H-WP power distribution unit (PDU) Black
Specs & where to buy

APC IT Power Distribution Module 3x1 Pole 3 Wire 32A 3xIEC309
300cm, 360cm, 420cm
Specs & where to buy

APC Rack ATS, 230V, 32A, IEC309 in
(16)C13 (2)C19 out power distribution unit (PDU) Black
Specs & where to buy