APC MGE Galaxy 5000 uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA 90000 W 0 AC outlet(s)
- Form factor: Tower
- Product colour: Grey
- UPS topology: Double-conversion (Online)
- Output power capacity: 100 kVA
- Output power: 90000 W
- Battery type: External
All 44 specificationsProduct page at apc.com ↗
Versions
0 - 95%
5 - 90%
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Dual mains input:
Increases availability by allowing the UPS to be connected to two separate power sources.
Adjustable voltage sensitivity:
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Frequency and voltage regulation:
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Generator compatible:
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Parallel-capacity capable:
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Parallel-redundant capable:
Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy.
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Grey
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 100 kVA
- Output powerThe power that the device can produce.
- 90000 W
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- External
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL 1778, UL 924
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 90%
Show all 44 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Grey
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 100 kVA
- Output powerThe power that the device can produce.
- 90000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 408 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 600 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 45/65 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 480 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 600 V
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 92.9%
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- O
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 1%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 3%
Power
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- External
- Number of batteries supportedThe number of batteries that can be used with the product.
- 4
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 190 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 5646 mm
- DepthThe distance from the front to the back of something.
- 813 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1900 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 8974.5 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL 1778, UL 924
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 90%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 999.9 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 9000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Terminal
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- Terminal
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 0 AC outlet(s)
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 63 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 5866 mm
- Package depthThe distance from the front to the back of the packaging.
- 838 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 1930 mm
- Package weightWeight of the packaged product.
- 9000 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC MGE Galaxy 5000 uninterruptible power supply (UPS) Double-conversion (Online) 80 kVA
72000 W 0 AC outlet(s)

APC SURT1000RMXLI + WBEXTWAR3YR-SP-03 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA
700 W 6 AC outlet(s)

APC SMT3000RMJ2U uninterruptible power supply (UPS) 3 kVA
2700 W 8 AC outlet(s)

APC SYMMETRA PX 96/160KW WALL-MOUNTED MAINTENANCE BYPASS PANEL, 400V

APC MGE Galaxy 300 uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
8000 W

APC Smart-UPS RC 3000VA uninterruptible power supply (UPS) 3 kVA
2100 W 9 AC outlet(s)