APC MGE Galaxy 3500 uninterruptible power supply (UPS) 15 kVA
- Form factor: Tower
- Output power capacity: 15 kVA
- Number of phases: 3
- Nominal output voltage: 208 V
- Nominal input voltage: 208 V
- Certification: CSA,CSA C22.2 No. 107.1,UL 1778
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
MGE Galaxy 3500 Parallel Maintenance Bypass, up to 3 units 10-15kVA 208V Floormount
Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Parallel-capacity capable
Increases total power capacity by using multiple UPSs simultaneously.
Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high efficiency
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Front-access servicing
Simplifies installation and maintenance while minimizing space requirements.
User-replaceable air filters
Enables quick and simple replacement of air filters.
Battery replacement without tools
Allows quick, easy battery replacement.
Multiple levels of service
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like APC to do for you.
7x24 telephone technical support
Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it.
Built-in Web/SNMP management
Full-featured management via a Web browser as well as comprehensive management from a Network Management System.
Environmental Monitoring
Prevent equipment failure from a full range of threatening environmental conditions.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Audible alarms
Provides notification of changing utility power and UPS conditions
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Excellent footprint
Small UPS footprint provides maximum usage of valuable electrical room floorspace
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Specifications
Design
- Form factorThe shape or design of the product.
- Tower
Features
- Output power capacityThe maximum power that the device can produce.
- 15 kVA
- Input frequencyThe frequency (Hz) which is required to power the product.
- 60 Hz
Power
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 3
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 356 mm
- DepthThe distance from the front to the back of something.
- 838 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1486 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 121.8 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CSA,CSA C22.2 No. 107.1,UL 1778
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- 0 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 9000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Packaging data
- Package dimensions (WxDxH)The external width, depth, and height of the product's packaging, measured in mm.
- 723 x 1104 x 1663 mm
- Package weightWeight of the packaged product.
- 156.4 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC S20BLK uninterruptible power supply (UPS) 1.8 kVA 12 AC outlet(s)

APC MGE Galaxy 3500 uninterruptible power supply (UPS) 30 kVA
24000 W 1 AC outlet(s)

APC Smart-UPS VT 10 kVA uninterruptible power supply (UPS)
8000 W 1 AC outlet(s)

APC MGE Galaxy 3500 uninterruptible power supply (UPS) 10 kVA
8000 W 1 AC outlet(s)

APC Smart-UPS VT 10 kVA uninterruptible power supply (UPS)
8000 W 1 AC outlet(s)

APC MGE Galaxy 3500 uninterruptible power supply (UPS) 10 kVA
8000 W 1 AC outlet(s)