APC Metered Rack 5.7K VA PDU power distribution unit (PDU) Black
- Operating temperature (T-T): 0 - 45 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 0 - 95%
- Storage relative humidity (H-H): 0 - 95%
- Nominal input voltage: 208 V
- AC input frequency: 50 - 60 Hz
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
-Flash Upgradeable: Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only).
-High Power Density.
-InfraStruXure Manager compatible: Enables centralized management via the APC InfraStruXure Manager.
-Local and web-based monitoring: Status available to customers both in the data center and remotely.
-Multi-branch power input.
-Network management capability: Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet.
-Toolless mounting capability.
-Vertical mounting capability.
-Local Current Monitoring Display: The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
-Alarm Thresholds: Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability).
-Load Indicator LED: Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Specifications
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 56 mm
- DepthThe distance from the front to the back of something.
- 44 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1778 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 5.45 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- cUL,CSA C22.2 No. 60950-1-03,FCC Part 15 Class A,ICES-003,Industry Canada,UL 60950-1,UL
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 5700 VA
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 20 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 20 A
Features
- Cable lengthHow long the cable is.
- 0.91 m
Other features
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- NEMA L21-20P
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- (21) NEMA 5-20R (6) NEMA L6-20R
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Metered Rack 1.92kVA PDU power distribution unit (PDU) Black

APC Rack PDU,Metered,ZeroU,14.4kW power distribution unit (PDU) Black

APC 1U Rack Mountable 16A Automatic Transfer Switch power distribution unit (PDU) Black

APC Metered Rack 5.7kVA PDU - 21 x NEMA 5-20R, 6 x NEMA L6-20R - 5.7kV power distribution unit (PDU) Black

APC Basic Rack 4.992kVA power distribution unit (PDU) Black