APC InfraStruXure power distribution unit (PDU) Black
- Operating temperature (T-T): 0 - 40 °C
- Storage temperature (T-T): -15 - 45 °C
- Operating relative humidity (H-H): 0 - 95%
- Storage relative humidity (H-H): 0 - 95%
- Operating altitude: 0 - 999.9 m
- Non-operating altitude: 0 - 9000 m
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
InfraStruxure PDU 60kW 480V/208V
Designed to increase flexibility and agility of data center power distribution through a design that does not require a raised floor.
Load Test Port
Load test port provides simple connection for full testing of a Symmetra PX UPS
Local and web-based monitoring
Status available to customers both in the data center and remotely
Smallest footprint
Minimizes your real estate expenses
Circuit Breaker Panel
Provides breaker positions for distribution to racks and power zones
System mobility
PDU equipment can easily be relocated to accommodate a changing data center environment.
Wide Range of Applications
Configure-to-order process allows APC to configure, install, and test complete system before shipping
Transformer for Step-down or Step-up or Isolation
Step down transformer placed upstream of the UPS to avoid inrush current and saturation eliminating need to oversize transformer
Front-access servicing
Simplifies installation and maintenance while minimizing space requirements.
Specifications
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 610 mm
- DepthThe distance from the front to the back of something.
- 914 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 2057 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 460 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 999.9 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 9000 m
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL 60950
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 480 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 60 Hz
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 72 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 167 A
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 120 V
Design
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Monitored
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Packaging data
- Package weightWeight of the packaged product.
- 470 kg
- Package widthThe distance from one side of the packaging to the other.
- 914 mm
- Package depthThe distance from the front to the back of the packaging.
- 1219 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 2184 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC PD80F6FK1-M power distribution unit (PDU) Black

APC Rack PDU 2G, Switched, ZeroU, 20A, 208V
(7) C13 & (1) C19, L620 Cord

APC IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V L5-20 UL
1680cm power distribution unit (PDU) 3 AC outlet(s) Black

APC 22kVA PDU power distribution unit (PDU) 24 AC outlet(s) Black

APC PDM3450CS50-200 power distribution unit (PDU) 1 AC outlet(s) Black