APC GVSUPS30KB4HS uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA 30000 W
- Form factor: Tower
- Product colour: White
- UPS topology: Double-conversion (Online)
- Output power capacity: 30 kVA
- Output power: 30000 W
- Management card included
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
GVSUPS30KB4HS Features
- Galaxy VS UPS 30kW 400V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5x8
- Highly efficient, easy-to-deploy 30kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and 2 smart high-capacity modular battery strings, expandable to 4 strings for extended runtime. Runtime charts available in the Documents tab.
- Includes: Battery modules ship installed, Dust filter, EcoStruxure Ready ((UPS)), Installation guide, Integrated network management, Power modules ship installed, Start-Up Service
Documents
- ManualUser manual ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 30 kVA
- Output powerThe power that the device can produce.
- 30000 W
- Management card includedIndicates whether a dedicated network management card for remote monitoring and control is included with the unit.
- Yes
- Quick installation guideIndicates whether a simplified, fast-start manual is included with the product.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Show all 47 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 30 kVA
- Output powerThe power that the device can produce.
- 30000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 340 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 460 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 380 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 2.5:1
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 3%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 521 mm
- DepthThe distance from the front to the back of something.
- 847 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1485 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 460 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CSA C22.2 NO. 107.3, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 60721-4-2 Level 2M2, UL 1778 5th edition
Packaging content
- Management card includedIndicates whether a dedicated network management card for remote monitoring and control is included with the unit.
- Yes
- Quick installation guideIndicates whether a simplified, fast-start manual is included with the product.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 3000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery voltageThe voltage (V) of the battery.
- 480 V
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Hard Wire 3-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)
- SmartSlotIndicates whether the unit features a dedicated expansion slot for installing optional network management or communication cards.
- Yes
- SmartConnect portIndicates whether the device features a dedicated SmartConnect port for remote cloud management and monitoring.
- No
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 54 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload, Short circuit
Management features
- ECO modeIndicates whether the device features an energy-saving mode to reduce power consumption during operation.
- Yes
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 61 dB
Logistics data
- Harmonized System (HS) codeThe standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.
- 85078000
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 640 mm
- Package depthThe distance from the front to the back of the packaging.
- 990 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 1680 mm
- Package weightWeight of the packaged product.
- 490 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Galaxy VS UPS 40kW 400V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5x8
Specs & where to buy

APC Galaxy VS UPS 50kW 400V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5x8
Specs & where to buy

APC Galaxy VS UPS 150kW 400V for External Batteries, Start-up 5x8
Specs & where to buy

APC GVSUPS20KB4HS uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA
20000 W
Specs & where to buy

APC GVSUPS10KR0B5FS uninterruptible power supply (UPS) 10 kVA
10000 W
Specs & where to buy

APC GVSUPS20KB2HS uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA
20000 W
Specs & where to buy