APC GVSUPS100KRGS uninterruptible power supply (UPS) 100 kVA 100000 W
- Product colour: White
- Output power capacity: 100 kVA
- Output power: 100000 W
- Warranty period: 1 year(s)
- Manual
- Input current (max): 36 A
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Highly efficient, easy-to-deploy 100 kW, 480 V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and one additional power module for N+1 redundancy.
Specifications
Key specifications
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Output power capacityThe maximum power that the device can produce.
- 100 kVA
- Output powerThe power that the device can produce.
- 100000 W
- Warranty periodThe length of time the manufacturer guarantees the product against defects, typically expressed in months or years.
- 1 year(s)
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Input current (max)The maximum amount of electrical current that the product can safely conduct or receive, measured in amperes (A).
- 36 A
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 10 - 80%
Show all 42 specificationsShow key specifications only
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Control typeThe way in which the device is controlled.
- Touch
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP21
Features
- Output power capacityThe maximum power that the device can produce.
- 100 kVA
- Output powerThe power that the device can produce.
- 100000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 480 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 480 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40 - 70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 480 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 480 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- 1%
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 2.5:1
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 1%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 3%
Other features
- Warranty periodThe length of time the manufacturer guarantees the product against defects, typically expressed in months or years.
- 1 year(s)
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 521 mm
- DepthThe distance from the front to the back of something.
- 847 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1485 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 29 kg
Battery
- Battery includedIndicates whether the product is supplied with a battery.
- No
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
Packaging content
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Power
- Input current (max)The maximum amount of electrical current that the product can safely conduct or receive, measured in amperes (A).
- 36 A
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 149 A
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 10 - 80%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1000 m
- Heat dissipationThe heat generated by the power supply.
- 9499 BTU/h
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.7
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 64 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 990 mm
- Package depthThe distance from the front to the back of the packaging.
- 640 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 168 mm
- Package weightWeight of the packaged product.
- 250 kg
Logistics data
- Minimum order quantityThe smallest number of units that can be purchased in a single order, measured in pc(s).
- 1 pc(s)
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC SRV1KI-E uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA
900 W 3 AC outlet(s)

APC BVX1200LI-MS uninterruptible power supply (UPS) Line-Interactive 1.2 kVA
650 W 4 AC outlet(s)

APC Easy UPS On-Line, 1000VA/900W, Rackmount 2U, 230V, 3x IEC C13 outlets, Intelligent Card Slot, LCD, W/O rail kit

APC Easy UPS On-Line, 2000VA, Lithium-ion, Rack/Tower 4U, 230V, 6 IEC C13 outlets, Intelligent Card Slot, Extended runtime, W/ rail kit

APC SRV3KI-E uninterruptible power supply (UPS) Double-conversion (Online)
2700 W