APC G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA 36000 W 1 AC outlet(s)
- Form factor: Tower
- Product colour: Grey
- UPS topology: Double-conversion (Online)
- Output power capacity: 40 kVA
- Output power: 36000 W
- Manual
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Flexible Design
Available in a wide range of configurations to suit any operating environment
Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
Multiple levels of service
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like APC to do for you.
Technical support
Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Parallel-capacity capable
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency
Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
Parallel-redundant capable
Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Integrates with StruxureWare Central
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Network management capability
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
Documents
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Grey
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 40 kVA
- Output powerThe power that the device can produce.
- 36000 W
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Quick installation guideIndicates whether a simplified, fast-start manual is included with the product.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Show all 47 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Grey
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 40 kVA
- Output powerThe power that the device can produce.
- 36000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 323 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 477 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 45/65 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 380 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 1
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 2.5%
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 1110 mm
- DepthThe distance from the front to the back of something.
- 855 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1900 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 958 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDE
Packaging content
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Quick installation guideIndicates whether a simplified, fast-start manual is included with the product.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 12000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery voltageThe voltage (V) of the battery.
- 432 V
- Battery life (max)Maximum battery life. Mobile Mark (2002) is the standard often used to benchmark battery life time.
- 10 year(s)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 10 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Hard Wire 4-wire (3PH + G)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- Terminal
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 1 AC outlet(s)
- SmartSlotIndicates whether the unit features a dedicated expansion slot for installing optional network management or communication cards.
- Yes
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 190 A
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55.5 dB
- Web-based managementUsing a website/web application to manage something.
- Yes
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 1130 mm
- Package depthThe distance from the front to the back of the packaging.
- 960 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 2030 mm
- Package weightWeight of the packaged product.
- 978 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC G55TUPSU40HB15S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA
36000 W

APC G55TUPSU30HS uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA
27000 W 1 AC outlet(s)

APC G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA
90000 W

APC G55TUPSU30HB15S uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA
27000 W

APC G55TUPU100HXS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA
90000 W